PLC-WU3800 Basic Serial Command Specifications23/24“81” [CR]Status: Standby after Cooling Down due to lamp failureThis value is returned when Cooling Down operation due to lamp failure has beencompleted and the status has been moved to Standby. The status is kept until the nextoperation starts.7.5. Input Mode Read CommandCommand “CR1” [CR]Detail Get the selected Input No.ResponseAcceptable “%1” [CR]%1”1” = Computer 1 is selected”2” = Computer 2 is selected“3” = HDMI is selected“4” = Video is selected“5” = S-video is selected“6” =Network is selectedUnacceptable “?” [CR]7.6. Lamp Time Read CommandCommand “CR3” [CR]Detail Get the total lamp running hours (Not actual lamp used hour, but Eco modecorresponding value).ResponseAcceptable “%1” [CR]%1 Shows the time period with 5 digits numbers.Example “00410”[CR] shows 410 hoursUnacceptable “?” [CR]7.7. Setting Read CommandCommand “CR4” [CR]Detail Get screen setting status such as Ceiling / Rear.ResponseAcceptable “%1” [CR]%1“11”[CR] = Normal Screen Setting“10”[CR] = Picture is top/bottom reversed.(Status: Rear Ceiling ON)“01”[CR] = Picture is left/right reversed. (Status: Rear ON)“00”[CR] = Picture is top/bottom and left/right reversed.(Status: Ceiling ON)Unacceptable “?” [CR]