PLC-WU3800 Basic Serial Command Specifications9/246. Functional Execution Command6.1. Format6.1.1 PC issues a command in format as below.“C” COMMAND [CR]Command: two characters (See Basic Functional Execution Command Table)6.1.2 A projector changes received data to decode and returns a result after being ready toreceive next command.[ACK] CR 0x06 0x0D When received Functional Execution Commands.6.1.3 “ ” CR When the received data cannot be decoded.6.2. Command PipeliningWhen some functions need the command pipelining, the performance is the same as that of theremote control;6.2.1. System: issues any command every 100 ms.6.2.2. When receiving the appropriate command, the function is executed for 120 ms from themoment.6.2.3. When receiving the same command continuously within 120 ms, the function is executedfor another 120 ms from the moment.6.2.4. When there is no incoming command after 120 ms, the execution of pipelining is stopped.6.2.5. When the projector receives other incoming commands within 120ms, the execution ofpipelining is stopped.6.3. Transfer ExampleSwitch the projector to video mode with Basic Command.CommandPC → Projector “C” “0” “7” CRProjector → PC ACK CRProcessingA few ms - 5s