PLC-XC50/55 Basic Serial Command Specifications11/256.5. POWER ON CommandCommand “C00” [CR]DetailPower ONWhen already Power is ON, nothing is done.When sending this command during processing Countdown, Countdown isterminated.ResponseAcceptable [ACK] [CR]Unacceptable [CR]6.6. POWER OFF Command Quick Power OFFCommand “C01” [CR]DetailPower OFF (Standby)When Power is OFF with ON/STAND-BY button of the projector and remotecontrol, “Power OFF?” is displayed. However, as soon as this command is sent,Quick Power OFF is executed.Response Acceptable [ACK] [CR]Unacceptable [CR]6.7. POWER OFF CommandCommand “C02” [CR]DetailPower OFF (Standby).The command operates the same Power OFF function as ON/STAND-BY buttonof the projector and remote control.Once this command is sent, “Power OFF?” is displayed. If this command is sentagain while it is displayed, Power OFF is executed.When sending this command during Countdown, Countdown is terminated.Response Acceptable [ACK] [CR]Unacceptable [CR]6.8. Computer 1 CommandCommand “C05” [CR]DetailSelect Computer 1 Input.Although Input search mode is On1/On2, the operation does not start with thiscommand.Response Acceptable [ACK] [CR]Unacceptable [CR]6.9. Computer 2 CommandCommand “C06” [CR]DetailSelect Computer2 InputAlthough Input search mode is On1/On2, the operation does not start with thiscommand.Response Acceptable [ACK] [CR]Unacceptable [CR]