-23-Optical Parts Disassembly510Fig.81611When mounting or assembling the optical parts in the opti-cal unit, the parts must be mounted in the specified loca-tion and direction as shown in figure below.234812, Locations and DirectionsRugged surfaceis facing thisside.Point marker is printedon this side upPoint marker is printedon this side upNo. Parts Name1 Integrator lens (IN)2 Integrator lens (OUT)3 Prism beam splitter (PBS)4 Condenser lens (OUT)5 Dichroic mirror (B)6 Dichroic mirror (G)7 Condenser lens (G)8 Condenser lens (R)9 Relay Lens (OUT)10 Mirror (R)11 Condenser lens (B)12 Mirror (B)7Film attachedside is facing thisside.1098