-71-Electrical AdjustmentService Adjustment Data Table These initial values are the reference data written from theCPU ROM to memory IC when replaced new memory IC. Theadjustment items indicated with “✻” are required to readjust fol-lowing to the “Electrical adjustments”. Other items should beused with the initial data value.GROUP NO. ITEM FUNCTION RANGE INITIAL VALUE NOTE0 Temperature Monitor Indication0 MCP9801 Duct (Temp) Monitor (°C) Temp. Sensor (Intake) x 10 – –1 MCP9801 Inner (Temp) Monitor (°C) Temp. Sensor (Inner) x 10 – –2 Thermistor Monitor (°C) Temp. Thermistor (Inner) x 10 – –3 Thermistor Monitor DAC value – –1 Pressure Monitor Indication0 Pressure Monitor Pressure (Compensation No) DAC – –1 Pressure Monitor Pressure (Compensation Yes) DAC – –2 Pressure Monitor Pressure (Compensation Yes) [mmHg]3 Pressure Monitor Pressure (Compensation Yes) [hpa] – –4 Flow Sensor Monitor (Read only)0 Flow Sensor Monitor Flow Sensor – –10 RS232C Set0 Baud rate RS232C Baud rate (0 : 19200 / 1 : 9600) 0 / 1 011 PJ-Net Set0 Reset Disable PJ-Net Reset (0 : Enable / 1 : Disable) 0 / 1 020 Logo On/Off0 Logo On/Off (0 : Menu Operation / 1 : Prohibition) 0 / 1 030 Color Shading / Gamma Correction0 Color shading Correction On/Off (0 : Off / 1 : On) Not memorized 0 / 1 11 Gamma Correction On/Off (0 : Off / 1 : On) Not Memorized 0 / 1 140 Dimmer Control0 Dimmer On/Off (0 : Menu Operation / 1 : Off) 0 / 1 1 (Shipment:0)1 Dimmer Level LAMP1 (0 : 264W ~ 15 : 330W) 0 ~ 15 152 Dimmer Level LAMP2 (0 : 264W ~ 15 : 330W) 0 ~ 15 1550 Auto Picture Control0 Auto Picture On/Off (0 : Menu Operation / 1 : Off) 0 / 1 1 (Shipment:0)91 Projector Error Logs History0 Warning_Log_1 Latest Error Log 0 ~ 32767 0~ : : :49 Warning_Log_50 50th older Error Log 0 ~ 32767 050 Warning_Log_Reset Resets the logs when the value is set to 10. 0 ~ 10 0100 Shutter Operation0 PRE_MOTION Pre-Motion Enable (0: Enable, 1: Disable) 0 ~ 1 1 (Shipment:0)1 CMP_TRM Chattering Detection Time 0 ~ 65535 70002 OUT_DLY_TRM Output Time 0 ~ 65535 150003 CMP_CHK_CNT Detection Count 0 ~ 15 54 OPEN_DLY Open Delay Time 0 ~ 63 05 CLOSE_DLY Close Delay Time 0 ~ 63 0113 Lamp Reset Counter0 Lamp 1 Lamp 1 Total Reset Count 0 ~ 127 01 Lamp 2 Lamp 2 Total Reset Count 0 ~ 127 0115 Lamp Go Out0 Lamp Go Out 0 : Disable / 1 : Enable 0 / 1 0116 Lamp Replace Display0 Lamp Replace Display 0 : Disable / 1 : Enable 0 / 1 1117 Lamp Life Test0 Lamp Life Test Enable 0: Disable / 1: Enable For safety test 01 Lamp Om time 12 Lamp Off time 33 Lamp Total time 0118 Half Lamp Auto Change0 Half Lamp Auto Change ON/OFF 0: Off, 1: On 0 / 1 01 Half Lamp Timer Start unit: hour 0 ~ 24 02 Half Lamp Timer Interval unit: hour 1 ~ 255 243 Half Lamp Timer Count unit: hour - -4 Half Lamp Auto CHange Store 0: Clear after AC Off, 1: Not Clear after AC Off 0 / 1 0