PLC-XK2200 /2600 /XK3010 Expand Serial Command Functional Specifications57 / 739.7.6 CR_SYSTEM CommandCommand “CR_SYSTEM”[CR]Details Get selected SystemAcceptable “000_%1”[CR]Input isPC Analog“VGA1” -------------- VGA1 is selected“VGA2” -------------- VGA2 is selected“XGA1”-------------- XGA1 is selected“WXGA3” --------- WXGA3 is selected“1080i” ------------ 1080i is selected“1035i” ------------ 1035i is selected“720p” ------------- 720p is selected“575p” ------------- 575p is selected“480p” ------------- 480p is selected“575i” -------------- 575i is selected“480i” -------------- 480i is selected“MODE1” ------- Mode1 is selected“MODE10” -------------- Mode10 is selectedWhen there is no signal, projector returns error code”101”[CR]Input isY,Pb/Cb,Pr/Cr“AUTO” ----------- Auto is selected“1080i” ------------1080i is selected“1035i” ------------ 1035i is selected“720p” ------------- 720p is selected“575p” ------------- 575p is selected“480p” ------------- 480p is selected“575i” -------------- 575i is selected“480i” -------------- 480i is selectedProjector returns selected System status regardless of thesignal input.%1Input isVideo,S-Video“AUTO” --------------- Auto is selected“NTSC” --------------- NTSC is selected“NTSC443” ---------- NTSC4.43 is selected“PAL” ------------------ PAL is selected“SECAM” ------------- SECAM is selected“PAL M” ------------- PAL-M is selected“PAL N” ------------- AL-N is selectedProjector returns selected System status regardless of thesignal input.ResponseUnacceptable ““Error Code”[CR]