PLC-XK2200 /2600 /XK3010 Expand Serial Command Functional Specifications69 / 739.11.24 CR_FANCONTROL CommandCommand “CR_FANCONTROL”[CR]Details Get selected Fan control setting statusAcceptable “000_%a”[CR]%a“OFF” ----------------------- Fan control is OFF“ON1” ----------------------- Fan control is ON1“ON2” ----------------------- Fan control is ON2ResponseUnacceptable “Error Code” [CR]9.11.25 CR_DELAYCTRL CommandCommand “CR_DELAYCTRL”[CR]Details Get setting status of Video delay controlAcceptable “000_%1”[CR]%1 “ON” ----------------------- Video delay control is active“OFF” ---------------------- Video delay control is inactiveResponseUnacceptable “Error Code”[CR]9.11.26 CR_FILH CommandCommand “CR_FILH”[CR]Details Get Filter used timeAcceptable “000_%1”[CR]%1 “00000”~”99999” ------------------- 0 hour to 99999 hoursResponseUnacceptable “Error Code”[CR]9.11.27 CR_FILREPL CommandCommand “CR_FILREPL”[CR]Details Get the information of Filter replacement timeAcceptable “000_%1”[CR]%1 “1Y” ------------------- Over filter replacement time“1N” ------------------ Within filter replacement timeResponseUnacceptable “Error Code”[CR]9.11.28 CR_FILTIMER CommandCommand “CR_FILTIMER” [CR]Details Get setting time which filter warning OSD is displayedAcceptable “000_%1”[CR]%1“2000” ----------------- 2000 hours“3000” ----------------- 3000 hours“4000” ----------------- 4000 hours“OFF” ---------------- No OSD displayResponseUnacceptable “Error Code”[CR]