PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications11/286.4 Operation Requirements6.4.1 In the following status of projector, Available Functional Execution Commands are limited.Projector Status Available Functional Execution CommandsStandby Mode C00: POWER ONCountdown in processC00: POWER ON → Countdown is terminatedC01: POWER OFFC02: POWER OFF → Countdown is terminatedC46: ZOOM -C47: ZOOM +C4A: FOCUS -C4B: FOCUS +C5D: LENS SHIFT UPC5E: LENS SHIFT DOWNC5F:LENS SHIFT LEFTC60:LENS SHIFT RIGHTWhen ZOOM+/-, FOCUS +/-, LENS SHIFTUP/DOWN/LEFT/RIGHT are executed during Countdownis in process, POINTER UP/DOWN(C3C/C3D)become effective, and ZOOM/FOCUS/LENS SHIFTbecome enable to control by POINTER UP/DOWN.*Pointer Command(C3A/CA3B/C3C/C3D)Cooling Down in process NONE (No Execution)Cooling Down due to AbnormalTemperature NONE (No Execution)Abnormal Temperature Status NONE (No Execution)Abnormal Power Status NONE (No Execution)Abnormal Filter Status NONE (No Execution)Power-Save Cooling Down in process NONE (No Execution)Power Save Status C00: POWER ONC01: POWER OFFCooling Down in process after OFFoperation due to Lamp Failure NONE (No Execution)Input button:Mode2 / Mode3 setting Although transmit Input source commands, Inputsearch does not operate.Note) in above status, the projector returns [ACK] [CR] even if it receives the other command.6.4.2 Functional Execution Commands are invalid when projector is in standby and “Eco” modeselected in Standby mode menu.