-77-Troubleshootingthe projector is detecting abnormal condition.IndicatorsProjector conditionPOWERgreenLAMPredWARNINGTEMP.redWARNINGFILTERorangeSHUTTERblueLAMPREPLACEorangeThe temperature inside the projector is elevated close to theabnormally high level.The temperature inside the projector is abnormally high. Theprojector cannot be turned on. When the projector is cooleddown enough and the temperature returns to normal, thePOWER indicator lights green and the projector can be turnedon. (The WARNING TEMP. indicator keeps blinking.) Checkand replace the filter.The projector has been cooled down enough and thetemperature returns to normal. When turning on the projector,the WARNING TEMP. indicator stops blinking. Check andreplace the filter.The lamp cannot light up. (The projector is preparing forstand-by or the projection lamp is being cooled down. Theprojector cannot be turned on until cooling is completed.)The lamp cannot light up. (The lamp has been cooled downenough and the projector is in stand-by mode and ready to beturned on with the ON/STAND-BY button.)The lamp has been used overtime. Replace the lampimmediately.When the filter detects clogging, reaches a time set in the timer setting or runs out of the filter scroll, the WARNINGFILTER indicator lights orange. When this indicator lights orange, replace the filter or the filter cartridge with a new onepromptly. Reset the Filter counter and Scroll counter after replacing the filter cartridge.ggggWhen the projection lamp reaches its end of life, the LAMP REPLACE indicator lights orange. When this indicator lightsorange, replace the projection lamp with a new one promptly.WArNING FILterLAMP rePLAceggggg❖❖❖❖❖ggggggggg