75The projector is detecting abnormal conditionIndicatorsProjector ConditionPOWERgreen / redWARNINGTEMP.redWARNINGFILTERorangeSHUTTERblueLAMP 1/2REP.yellowThe temperature inside the projector is elevated close tothe abnormally high level.The temperature inside the projector is abnormally high.The projector cannot be turned on. When the projectoris cooled down enough and the temperature returns tonormal, the POWER indicator lights red and the projectorcan be turned on. (The WARNING TEMP. indicator keepsblinking.) Check and replace the filter.The projector has been cooled down enough and thetemperature returns to normal. When turning on theprojector, the WARNING TEMP. indicator stops blinking.Check and replace the filter.The lamp cannot light up. (The projector is preparing forstand-by or the projection lamp is being cooled down. Theprojector cannot be turned on until cooling is completed.)The lamp cannot light up. (The lamp has been cooleddown enough and the projector is in stand-by mode andready to be turned on with the ON/STAND-BY button.)When either of the 2 lamps is out.The lamp has been used overtime. Replace the lampimmediately.✽✽✽✽✽✽✽When the filter detects clogging, reaches a time set in the timer setting or runs out of the filter scroll, the WARNINGFILTER indicator lights orange. When this indicator lights orange, replace the filter or the filter cartridge with a newone promptly. Reset the Filter counter and Scroll counter after replacing the filter cartridge (p.63).✽✽✽✽✽✽✽✽✽✽✽✽ ✽WARNING FILTERWhen the LAMP 1 REPLACE indicator and the LAMP 2 REPLACE indicator light yellow, replace the projection lampswith new ones promptly. See pages 52, 64- 66.LAMP 1/2 REPLACE✽✽redgreenredredredgreenAppendix