Chapter 2. Menu Operations332.3.3.5 Ribbon SpeedProvides a means to vary the Ribbon Motor speed for a Ribbon Motor Test.Speed selections: 1–250, Default.2.3.3.6 Paper Out TholdThis parameter allows you to set the Paper Out Threshold value for the Paper Out Sensor. Byusing this, you can compensate for the reflectivity of different types of paper.Selections are 1- 255.2.3.3.7 ClearThis parameter provides you with a means of clearing portions of NVRAM to factory defaultsettings.2.3.3.7.1 CountsClears the count information from NVRAM, and clears the Fault Log.2.3.3.7.2 CalibrationsClears the calibration data from NVRAM. When CalData is selected you must perform Hammerand Paper Calibration routines before using the printer.2.3.3.7.3 NVRAMClears the application configuration portion of NVRAM.2.3.3.8 Shuttle OffThis parameter allows you to set the amount of time the shuttle remains at speed after the lastprinted data.Options are 10 Sec, 20 Sec, 30 Sec, and 60 Sec.2.3.3.9 Serial DumpWhen this parameter is enabled, the data the printer receives from the parallel port of PSIO cardsis replicated and sent out from the serial port. This allows you to connect a serial cable from theprinter to a computer and capture the data using a serial capture utility.2.3.3.10 Serial NumberThis parameter provides for the entry of a unique printer serial number. Each digit is entered in thesame manner as that used to enter a configuration name.