Operator Manual3–16Configuration MenuFollowing are explanations of each menu category and parameter. For allavailable selections under each parameter below, consult the Help Menuprintout.Printer CategoryPowerupThis parameter sets the printer either Online or Offline when the power switchis turned on. This parameter setting is automatically saved to the PowerupConfiguration when it is changed. The default is Offline.Ser/Par EmulThis parameter allows you to define which set of printer control commands willbe emulated for data received on the Serial and Parallel ports (except LAN-IPDS). This parameter setting is automatically saved in the Powerup Configu-ration. MT660 is the default selection.When a new emulation setting is entered through the Printer Control Panel,emulation dependent parameters in the Current and Powerup configurationsare changed to match the default settings for the selected emulation. Thefollowing table lists those parameters by emulation:Parameter Tally ANSI Genicom ANSI P5000 P6000 P600Character Set Latin1 Code Pg 437 Code Pg 850 Latin1 Latin1OCR-A ANSI ANSI ANSI ANSI ANSIOCR-B ANSI ANSI ANSI ANSI ANSIAuto CR OFF ON ON ON OFFLineWrap OFF ON OFF OFF OFFWrap LF OFF ON OFF OFF OFFCode 7F FILL FILL Space Space SpaceVT Channel 2 12 N/A 12 12SkipWhen Before Before N/A After AfterParameter HP 2564C DEC LG01 Epson FX-1180 IBM Proprinter MTPLCharacter Set Roman-8 DEC Italic Code Pg 437 Code Pg 437OCR-A ANSI ANSI ANSI ANSI ANSIOCR-B ANSI DIN ANSI ANSI ANSIAuto CR OFF OFF ON ON ONLineWrap OFF OFF ON ON ONWrap LF OFF OFF ON ON ONCode 7F Fill FILL Delete Char Ignore Delete BufferVT Channel 12 12 N/A N/A N/ASkipWhen After After N/A N/A N/A