TASCAM DA-6400/DA-6400dp 31DA-6400/DA-6400dpFunction added to set the input and output signal routing for each individual channelInput signal routing can now be set per channel. Output signalrouting can also now be set per channel.The INPUT ROUTING 1 and INPUT ROUTING 2 menu pageshave been replaced by a ROUTING page for these functions.Setting input signal routingFollow these steps to set input signal routing.1. Open the ROUTING page and select the INPUT ROUTINGitem. Then, press the MULTI JOG dial to open the INPUTROUTING settings list.INPUT ROUTING settings listNOTEWhen an interface card with less than 64 input signal channelsis installed, the names of unavailable input connectors appeargray.For example, if an IF-AE16 card with 16 I/O channels is in-stalled in SLOT1, the SLOT1-17 IN to SLOT1-64 INitems will appear gray.2. Turn the MULTI JOG dial to select the channel you wantto set, and press the MULTI JOG dial to open the INPUTROUTING setting screen.INPUT ROUTING setting screen3. Select the EDIT MODE item and set how setting values arechanged.Press the MULTI JOG dial to confirm the EDIT MODE andmove the cursor to the next item. You can also use the .and / buttons to move the cursor.OptionIndividual (default): Change settings for one channelat a time.8ch BLOCK: Change settings for eight channels at a time.BATCH SETUP: Set a group of multiple channels to bechanged at the same time.4. Operations differ according to the selected EDIT MODE.o Individual selectedThe name of the channel selected in step 1 appears to theleft of the selection area.Turn the MULTI JOG dial to select an input signal.Options: SLOT1-01 IN – SLOT1-64 IN,SLOT2-01 IN – SLOT2-64 IN(128 options)Press the MULTI JOG dial to confirm the setting value andreopen the INPUT ROUTING setting list.o 8ch BLOCK selectedAn 8-channel block that includes the channel selected instep 1 appears to the left of the selection area.Turn the MULTI JOG dial to select an input signal block.Options: SLOT1 01-08, SLOT1 09-16,SLOT1 17-24, SLOT1 25-32,SLOT1 33-40, SLOT1 41-48,SLOT1 49-56, SLOT1 57-64,SLOT2 01-08, SLOT2 09-16,SLOT2 17-24, SLOT2 25-32,SLOT2 33-40, SLOT2 41-48,SLOT2 49-56, SLOT2 57-64 (16 options)Press the MULTI JOG dial to confirm the setting value andreopen the INPUT ROUTING setting list.o BATCH SETUP selectedRANGE SELECT appears to the left of the selection area.Press the MULTI JOG or . and /buttons to move theblue cursor, and turn the MULTI JOG to set the followingvalues.o First and last numbers of the range of channels forwhich you want to change settingso Slot number and input connector starting number forthe input signal you want to routeMove the blue cursor to APPLY and press the MULTI JOGdial to open a pop-up confirmation message.