42 TASCAM SS-CDR200/SS-R200/SS-R1003 Select OTHERS.4 Press the MULTI JOG dial or , [LOCK] button (orremote control ENTER or t button) to open theREC OTHERS screen.5 Select SRC.6 Press the MULTI JOG dial or , [LOCK] button (orremote control ENTER or t button) to move thecursor right to select the value.7 Turn the MULTI JOG dial (or press the remotecontrol 5 and b buttons) to set it to ON (defaultvalue: OFF).8 When you have finished making the setting, pressthe HOME/DISPLAY button (or remote controlHOME/DISP button) to return to the Home Screen.NOTEIf a digital signal with a sampling frequency that•differs from the sampling frequency specified in theREC FORMAT item is being received at the DIGITALIN jack, and you attempt to record with SRC off, an FSUNMATCH error message will appear.The sampling rate converter (SRC) setting is retained•even after the power is turned OFF.Monitoring the input signalWhen you press the front panel or remote controlRECORD button to enter recording standby, the RECORDand READY buttons light, and the input signal will beoutput from the various output jacks (headphones, analogbalanced, analog unbalanced and digital). In addition, themeters on the home screen will show the input level.To end recording standby, press the front panel or remotecontrol STOP button.TIPIf you simply want to monitor the input signal without•intending to record anything, press the RECORD keywithout any media in the current device. MONITOR willappear on the display, and the RECORD button willblink red.To stop monitoring the input signal, press the• STOPbutton on the front panel or remote control.Adjusting the input signal level andbalanceYou can use the menu to adjust the level and balance ofthe input signal.Follow the instructions in the “Monitoring the inputsignal” section above to enable monitoring of the inputsignal, and then follow these procedures.1 Press the MENU [JOG] button (or remote controlMENU button) to open the MENU screen.2 Open the REC menu.3 Select INPUT VOLUME.4 Press the MULTI JOG dial or , [LOCK] button (orremote control ENTER or t button) to open a pop-up with the INPUT VOLUME settings.5 Set the following INPUT VOLUME items.LEVELAdjust the input level.Options: –inf, –54dB – 0.0dB (default value) – +18dBBALANCEAdjust the input balance.Options: L50 – C (center, default value) – R50NOTEThe level meter will show• OVER at –0.2 dBfs.Since the level meter appears on the Home Screen at•the top of the display, you can check the input level asyou adjust it. Set the level as high as possible withoutmaking the OVER indicator to the right of the meterappear.6 When you have finished making the setting, pressthe HOME/DISPLAY button (or remote controlHOME/DISP button) to return to the Home Screen.NOTEThe input LEVEL and BALANCE settings are retained evenafter the power is turned OFF.Basic recording operationsYou can begin recording after you have finished makingthe above settings (input source selection, recording fileformat setting, sampling rate converter ON/OFF, inputlevel adjustment).To start recording standby from a stopped state:Press the front panel or remote control RECORD buttonto put the unit in recording standby (The RECORD andREADY buttons light).To start recording from recording standby:Press the front panel or remote control PLAY button.To switch from recording to recording standby:Press the front panel or remote control READY button.5 – Recording