First Edition • Fifth Printing Operator's ManualWork Area SafetyPart No. 215595GT GS™-2669DC • GS™-3369DC • GS™-4069DC 9Work Ar ea SafetyElectrocution HazardsThis machine is not electrically insulated and willnot provide protection from contact with orproximity to electrical current.Obey all local andgovernmentalregulations regardingrequired clearance fromelectrical power lines. Ata minimum, the requiredclearance contained inthe chart below must befollowed.Line Voltage Required Clearance0 to 50KV 3.05 m50 to 200KV 4.60 m200 to 350KV 6.10 m350 to 500KV 7.62 m500 to 750KV 10.67 m750 to 1000KV 13.72 mAllow for platform movement, electrical line sway orsag, and beware of strong or gusty winds.Keep away from themachine if it contactsenergized power lines.Personnel on the groundor in the platform must nottouch or operate themachine until energizedpower lines are shut off.Do not operate the machine during lightning orstorms.Do not use the machine as a ground for welding.Tip-over HazardsOccupants, equipment and materials shall notexceed the maximum platform capacity or themaximum platform capacity of the platformextension.Maximum capacity – GS-2669DCPlatform retracted 680 kgPlatform extended – Platform onlyPlatform extended – Extension only544 kg136 kgMaximum occupants Indoor –4Outdoor –4680 kg 136 kg 544 kgMaximum capacity – GS-3369DCPlatform retracted 454 kgPlatform extended – Platform onlyPlatform extended – Extension only318 kg136 kgMaximum occupants Indoor use –4Outdoor use – 2454 kg 136 kg 318 kg