Sixth Edition • First Printing Operator's ManualOperating InstructionsPart No. 1299167GT Z®-45/25J 57Aircraft Protection Package (if equipped)If the platform bumper comesinto contact with an object, themachine will shut down and nofunctions will operate.1 Start the engine.2 Press down the foot switch.3 Move and hold the aircraftprotection override switch.4 Move the appropriatefunction control handle ortoggle switch to move themachine away from aircraftcomponents.Control Box Heater (if equipped)Move the control box heater switch upto activate the heater.Engine Shut-down indicator light (ifequipped)Light on: Tag and remove the machinefrom service.LCD Screen (if equipped)The LCD screen displays hourmeter, voltage, oil pressure andcoolant temperature. Thescreen also displays fault codesand other service information.Perkins EngineMachines equipped with Perkins diesel engineswith an LCD screen have a regeneration modethat should run automatically when needed.Left amber light on and high temperature text boxpresent: Regeneration mode is running. Noservice required.Right side amber light on or flashing: Regenerationis required.1 Push in red Emergency Stop button to turn themachine off.2 Restart the engine. The regeneration modeshould run automatically.Left amber light on and no high temperature textbox present: Regeneration mode is turned off. Toturn the regeneration mode on:1 Push in red Emergency Stop button to turn themachine off.2 Restart the engineFlashing red lights: contact service personnel.Flashing green lights: contact service personnelwithin 24 hours.Deutz engineFlashing red lights: contact service personnel.Flashing green lights: contact service personnelwithin 24 hours.