OneLINK For RoboSHOT HDMI CamerasOneLINK For RoboSHOT HDMI Cameras Page 7 of 20BASIC S YSTEM CONFIGURATION :The OneLINK HDMI EZIM and OneLINK HDMI Interface are connected to each other with one Cat-5e or bettercable plugged into the purple “OneLINK” ports at either end.InstallationStep 1: Connect the 1’ (305mm) cables from the OneLINK EZIM to the camera. There will be a power cable, Cat-5e patch cables for RS-232 and Network and an HDMI M to M cable.Step 2: Connect the OneLINK ports with a quality Cat-5e cable. In noisier RF or EMF environments - when in doubt,use shielded Cat-6 cable. Cable distance between the OneLINK EZIM and Interface is a maximum of 328 feet (100 m).Step 3: At the OneLINK Interface, Connect the HDMI Output to the video destination (monitor, switcher, console controller,etc…), connect the control sources RS-232 or network control or both. Connect the 48 VDC, 1.36 Amp power supply to theOneLINK HDMI Interface. The camera will boot up, calibrate the direct drive motors and in a few moments, the camera is readyfor operation.Please see the camera manual for setup and configuration of the video and other camera settings.Diagram: Basic Connectivity of the OneLINK SystemRoboSHOT 30 HDMI Camera(Cameras are sold separately)RS-232HDMI VideoSimulated dolphins in a simulateddolphin poolProductionVIEW™ PrecisionCamera ControllerPowerOneLINK Digital BusVideo, Power and Control up to328’ (100m) on Cat-5e/6 Cable48 VDC,1.36 AmpPower SupplyEthernetPC for CameraConfiguration andControlOneLINK HDMI InterfaceOneLINK EZIMCamera InterfaceRS-232 Cat-5eHDMIVideoEthernet NetworkSwitchEthernet