20 • vacon TECHNICAL DATA44.2.2 Vacon NX_6 – Mains voltage 525—690 VHigh overload = Max current IS, 2 sec/20 sec, 150% overloadability, 1 min/10 minFollowing continuous operation at rated output current, 150 % rated output current (IH)for 1 min, followed by a period of load current less than rated current, and of suchduration that the r.m.s output current, over the duty cycle, does not exceed ratedoutput current (IH)Low overload = Max current IS, 2 sec/20 sec, 110% overloadability, 1 min/10 minFollowing continuous operation at rated output current, 110% rated output current (IL)for 1 min, followed by a period of load current less than rated current, and of suchduration that the r.m.s output current, over the duty cycle, does not exceed ratedoutput current (IL)All sizes are available as IP21/NEMA1 Sizes FR4 to FR10 are additionally available as IP54/NEMA12.FR12 is available only as NXP.Mains voltage 525-690 V, 50/60 Hz, 3~AC drivetype Loadability Motor shaft powerFrameDimensions andweightWxHxD/kg(in/lb)Low High 690V supply 575V supplyRatedcontinuouscurrent IL(A)10%overloadcurrent(A)Ratedcontinuouscurrent IH(A)50%overloadcurrent(A)MaxcurrentIS10%overload104 °FP(HP)50%overload122 °FP(HP)10%overload104 °FP(hp)50%overload122 °FP(hp)NX_ 0004 6 4.5 5.0 3.2 4.8 6.4 4 3 3.0 2.0 FR6 7.7x20.4x9.3/40.8NX_ 0005 6 5.5 6.1 4.5 6.8 9.0 5.4 4 3.0 3.0 FR6 7.7x20.4x9.3/40.8NX_ 0007 6 7.5 8.3 5.5 8.3 11.0 7.4 5.4 5.0 3.0 FR6 7.7x20.4x9.3/40.8NX_ 0010 6 10 11.0 7.5 11.3 15.0 10 7.4 7.5 5.0 FR6 7.7x20.4x9.3/40.8NX_ 0013 6 13.5 14.9 10 15.0 20.0 13 10 11 7.5 FR6 7.7x20.4x9.3/40.8NX_ 0018 6 18 19.8 13.5 20.3 27 20 13 15 11 FR6 7.7x20.4x9.3/40.8NX_ 0022 6 22 24.2 18 27.0 36 25 20 20 15 FR6 7.7x20.4x9.3/40.8NX_ 0027 6 27 29.7 22 33.0 44 29.4 25 25 20 FR6 7.7x20.4x9.3/40.8NX_ 0034 6 34 37 27 41 54 40 29.4 30 25 FR6 7.7x20.4x9.3/40.8NX_ 0041 6 41 45 34 51 68 50 40 40 30 FR7 9.3x23.3x10.1/77.2NX_ 0052 6 52 57 41 62 82 60 50 50 40 FR7 9.3x23.3x10.1/77.2NX_ 0062 6 62 68 52 78 104 74 60 60 50 FR8 11.5x29.8x13.5/128NX_ 0080 6 80 88 62 93 124 101 74 75 60 FR8 11.5x29.8x13.5/128NX_ 0100 6 100 110 80 120 160 121 101 100 75 FR8 11.5x29.8x13.5/128NX_ 0125 6 125 138 100 150 200 147 121 125 100 FR9 18.9x45.3x14.3/322NX_ 0144 6 144 158 125 188 213 177 147 150 125 FR9 18.9x45.3x14.3/322NX_ 0170 6 170 187 144 216 245 214 177 150 150 FR9 18.9x45.3x14.3/322NX_ 0208 6 208 229 170 255 289 268 214 200 150 FR9 18.9x45.3x14.3/322NX_ 0261 6 261 287 208 312 375 335 268 250 200 FR10 23.4x79.4x23.7/749.6NX_ 0325 6 325 358 261 392 470 422 335 300 250 FR10 23.4x79.4x23.7/749.6NX_ 0385 6 385 424 325 488 585 476 422 400 300 FR10 23.4x79.4x23.7/749.6NX_ 0416 6 416 458 325 488 585 536 422 450 300 FR10 23.4x79.4x23.7/749.6NX_ 0460 6 460 506 385 578 693 603 476 450 400 FR11 31.3x79.4x23.7/882NX_ 0502 6 502 552 460 690 828 670 603 500 450 FR11 31.3x79.4x23.7/882NX_ 0590 6 590 649 502 753 904 751 670 600 500 FR11 31.3x79.4x23.7/1036NXP 0650 6 650 715 590 885 1062 845 751 650 600 FR12 47.6x79.4x23.7/1323NXP 0750 6 750 825 650 975 1170 952 845 800 650 FR12 47.6x79.4x23.7/1323NXP 0820 6 820 902 650 975 1170 1072 845 800 650 FR12 47.6x79.4x23.7/1323Table 4-2. Power ratings and dimensions of Vacon NX_, supply voltage 525—690V.Note: The rated currents in given ambient temperatures are achieved only when the switching frequency is equal toor less than the factory default.Note: The rated currents for FR10 to FR12 are valid at an ambient temperature of 104 qF (except for 0416 6, 0590 6and 0820 6: rated currents valid at an ambient temperature of 95 °F).Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com