Split Type Installation Manual85.6 Technical SpecificationsUnits V 12-025 W V 12-035 W V 12-050 W V 12-060 WIndoor Unit V 12-025 HWI V 12-035 HWI V 12-050 HWI V 12-060 HWIOutdoor Unit V 12-025 HWO V 12-035 HWO V 12-050 HWO V 12-060 HWOCooling Capacity kW 2,86 3,40 5,40 6,70Power input kW 0,89 1,05 1,68 2,09Operating current A 3,90 4,40 6,80 9,20Heating capacity kW 2,95 3,79 6,05 7,05Power input kW 0,81 1,05 1,68 2,05Operating current A 3,40 4,60 6,90 8,70Indoor UnitAir Flow volume m3/h 355/391/450 391/455/500 672/736/800 708/804/900Sound Power level dB(A) 45/52/56 45/52/56 47/54/59 52/52/56Sound Pressure level dB(A) 28/34/40 30/37/42 32/39/43 42/44/46Dimensions (HxLxD) mm 250x745x195 250x745x195 292x900x215 292x900x215Net Weight kg 9 9 14 14Outdoor UnitAir Flow volume m3/h 1700 1700 2000 2400Sound Power level dB(A) 63 63 66 67Sound Pressure level dB(A) 50 50 53 54Refrigerant R410A R410A R410A R410ARefrigerant charge gr 560 870 1500 1900Expansion system CAPILLARY CAPILLARY CAPILLARY CAPILLARYDimensions (HxLxD) mm 500x700x225 540x795x255 540x795x255 605x850x295Dimensions Valves A/B/C mm 45x55x159,5 50x55x159,5 50x55x159,5 45/55/165Dimensions Installation I/J mm 260x510 280x510 280x510 305/500Net Weight kg 25 36 39 45Pipe ConnectionsPipe conection diameter liq/gas Inches 1/4 - 3/8 1/4 - 3/8 1/4-1/2 1/4-1/2PM bar 42 42 42 42pm bar 13 13 13 13Maximum piping length m 20 20 25 25Max. height IU under OU m 10 10 15 15Max. height OU under IU m 10 10 15 15Chargeless length m 7,5 7,5 7,5 7,5Additional charge per metre gr 28 28 40 50Table 5.5 Technical specifications. (MONO).5 Description of the Unit