4 Set-up8 Installation and maintenance instructions ecoTEC plus 0020134823_073.1.2 Functional element (1006/5‑5 and 1206/5‑5)123675481091213141516111 Connection for theair/flue pipe2 Fan3 Gas pipe4 Supply air connector5 Flue pressure switch6 Return temperaturesensor7 Safety cut-out (flue gas)8 Water pressure sensor9 Electronics box10 Integral condensationheat exchanger11 Manometer12 Flow temperaturesensor13 Safety cut-out14 Ignition electrode15 Automatic air vent16 Monitoring electrode3.2 Information on the data plateThe data plate is mounted on the underside of the product atthe factory.Information on theidentification plateMeaningSerial number for identification; 7th to 16th digits =product article numberVU… Vaillant gas-fired wall-hung boiler forheatingecoTEC plus Product designationH, G20 – 20 mbar(2.0 kPa)Gas group and gas connection pressureas set at the factoryCat. (e.g. II2H3P) Unit categoryTypes (e.g. C33) Gas-fired boiler typesPMS (e.g. 6 bar(0.6 MPa))Permissible total overpressureTmax. (e.g. 85 °C) Max. flow temperature230 V 50 Hz Electric connection(e.g. 260) W Max. electrical power consumptionInformation on theidentification plateMeaningIP (e.g. X4D) Level of protectionHeating modeP Nominal heat output rangeQ Heat input rangeNoteMake absolutely sure that the product is compat-ible with the gas group at the installation site.3.3 CE markingThe CE marking shows that the products comply with thebasic requirements of the applicable directives as stated onthe data plate.The declaration of conformity can be viewed at the manufac-turer's site.4 Set-upFor fault-free operation and a long service life for theproduct, you must only install the product in installations withsystem separation (plate heat exchanger).4.1 Unpacking the product1. Remove the product from its box.2. Remove the protective film from all parts of the product.4.2 Checking the scope of delivery▶ Check that the scope of delivery is complete and intact.4.2.1 Scope of deliveryNum-ber Designation1 Unit mounting bracket1 Heat generator1 Condensate trap1 Condensate discharge hose1 Mounting template1 Enclosed documentation1 Enclosed unit fastening1 Bag with small parts1 Gas connector1 Service valve (1 1/2 inches), red handle1 Service valve (1 1/2 inches), blue handle1 Bag with seals for service valves1 Expansion relief valve, 6 bar1 R 1 straight-through gas valve