VaporTEK Calibration Simulation with FB1 Terminal48Simulation with FB1 Terminal1. Press the START green button on the FB1 Terminal until the below screen appears. Press the keys as shown:2. When the display below appears, press the keys shown:3. When the display below appears, press the keys shown to start the simulation:4. At the display below, select the dispenser side (1 or 2) that you want to simulate:5. At the display below, select the simulation rate of petrol you want to check by pressing the keys shown:When the flow rate input is provided through the FB1 Terminal the VaporTEK pump will start if greater than 6liters/minute. The flow rate achieved by the VaporTEK Pump will be displayed in the FB1 Terminal.6. The FB1 Terminal will start the simulation and display the results as in the example below:*** SERVICE ***SAL – pump (1)S&B – pump (2)GIL – pump (3)*** SERVICE ***Gas measuring (1)SYS–Identify (2)EC2000 (3)2Service (1)Parameter (2)Autocalib (3)Simulation (4) 4Select SideSide 1 (1)Side 2 (2) 1 2or1 2 3or,SimulationMax 40 l/min (1)Max 35 l/min (2)Free Input (3)