7112 SupplementVEGAFLEX 82 • 4 … 20 mA/HART - two-wire44222-EN-17022012 Supplement12.1 Technical dataGeneral data316L corresponds to 1.4404 or 1.4435Materials, wetted partsƲ Process fitting 316L and PPS GF 40, Alloy C22 (2.4602) and PPS GF40Ʋ Process seal on the instrument side(cable/rod leadthrough)FKM (SHS FPM 70C3 GLT), FFKM (Kalrez 6375),EPDM (A+P 75.5/KW75F)Ʋ Process seal On site (instruments with thread: Klingersil C-4400 isenclosed)Ʋ Inner conductor (up to the separationcable/rod)316LƲ Rod: ø 16 mm (0.63 in) 316L or Alloy C22 (2.4602)Ʋ Cable: ø 4 mm (0.157 in) 316 (1.4401)Ʋ Cable: ø 6 mm (0.236 in) - PA coated Steel (galvanized), PA coatedƲ Cable: ø 6 mm (0.236 in) 316 (1.4401)Ʋ Cable: ø 11 mm (0.433 in) - PA coated Steel (galvanized), PA coatedƲ Gravity weight (optionally available) 316LMaterials, non-wetted partsƲ Plastic housing plastic PBT (Polyester)Ʋ Aluminium die-cast housing Aluminium die-casting AlSi10Mg, powder-coated - basis:PolyesterƲ Stainless steel housing (precisioncasting)316LƲ Stainless steel housing (electropol-ished)316LƲ Second Line of Defense (optional)1) Borosilicate glass GPC 540Ʋ Seal between housing and housing lid Silicone SI 850 RƲ Inspection window in housing cover(optional)Polycarbonate (with Ex d version: glass)Ʋ Ground terminal 316LƲ Cable gland PA, stainless steel, brassƲ Sealing, cable gland NBRƲ Blind plug, cable gland PASecond Line of Defense (optional)2)Ʋ Supporting material 316LƲ Glass potting Borosilicate glass GPC 540Ʋ Contacts Alloy C22 (2.4602)Ʋ Helium leak rate < 10-6 mbar l/s1) Only with Ex-d version.2) Only with Ex-d version.