145 Set up with the display and adjustment moduleVEGAPULS 61 • Profibus PA47106-EN-1611041 2Fig. 11: Installing the display and adjustment module in the double chamberhousing1 In the electronics compartment2 In the terminal compartmentNote:If you intend to retrofit the instrument with a display and adjustmentmodule for continuous measured value indication, a higher lid with aninspection glass is required.5.2 Parameter adjustment1. Go to the menu "Setup" via the display and adjustment module.2. In the menu item "Medium"you select the medium of your applica-tion, for example "Aqueous solution".3. Select in the menu item "Application" the vessel, the applicationand the vessel form, for example, storage tank.4. Carry out the adjustment in the menu items "Min. adjustment" and"Max. adjustment".Set parameters