67PROTEC 2KOPERATING MANUALVERSION 02/2016 ORDER NUMBER DOC23528248.1.4 DECOMMISSIONING AND CLEANING9. Fully assemble the system.10. Check fi ll level of the separating agent Chapter 8.2.3.3.11. Fill the system with flushing agent in accordance with Chapter 8.2.5.When storing the device for longer periods of time, it is necessary to thoroughly clean itand protect it from corrosion. Replace the water or solvent in the product pump with asuitable preservative, fill separating agent cup with separating agent.Procedure:1. Carry out points 1 to 10 of Chapter 8.1.4 "Decommissioning and Cleaning".2. Fill the system with preservative in accordance with Chapter 8.2.5.3. Empty the pump in a controlled manner in accordance with Chapter 8.2.4 and seal theopenings.8.1.5 LONG-TERM STORAGEThe device should be cleaned for maintenance purposes. Ensure that no remaining productdries on and sticks to the device.1. Carry out work interruption Chapter 7.5.2. Perform intermediate flushing Chapter 7.6.3. Perform paint change flushing Chapter 7.7.1.4. Empty the pump in a controlled manner in accordance with Chapter 8.2.4.5. Maintain the gun according to the operating manual.6. Clean and check the suction system and the suction filter.7. Product filter: check and clean/replace filter insert and filter body. Chapter 8.2.6.8. Clean the outside of the system.Brittle filter pressure regulator!The tank on the filter pressure regulator becomes brittle throughcontact with solvents and can burst.Flying parts can cause injury.Do not clean the tank on the filter pressure regulator with solvents.WARNINGGas mixtures can explode if there is an incompletely filled pump!Danger to life from flying parts.Ignition of potentially explosive surrounding atmosphere.Ensure that the pump and suction system are always completelyfilled with fl ushing agent or working material.Do not spray the device empty after cleaning.WARNING