WAGO 750-630/040-001 Manual
Also see for 750-602/040-000: Manual
WAGO-I/O-SYSTEM 750 XTR Use in Hazardous Environments 47750-630/040-001 SSI Interface Adjust XTRManualVersion 1.1.0Pos : 34.18 /Alle Serien (Allgemeine M odul e)/Übersc hriften/Ebene 2/Errichtungs besti mmungen - Ü berschrift 2 @ 3\mod_1232453624234_21.doc x @ 26370 @ 2 @ 18.2 Installation RegulationsPos : 34.19 /Alle Serien (Allgemeine M odul e)/Ei ns atz i n Ex-Bereic hen/Errichtungsbes timmungen Ei nleitung_2013 @ 14\mod_1360582328318_21.doc x @ 111371 @ @ 1For the installation and operation of electrical equipment in hazardous areas, thevalid national and international rules and regulations which are applicable at theinstallation location must be carefully followed.Pos : 34.20 /D okumentati on allgemei n/Gli ederungsel emente/----Leerz eile-(1Z)---- @ 28\mod_1485262995837_0.doc x @ 404006 @ @ 1Pos : null /Alle Serien ( Allgemei ne Modul e)/Ü bersc hriften/Ebene 3/Besonder e Hinweis e hinsic htlic h Expl osi ons schutz - Übersc hrift 3 @ 29\mod_1491558409838_21.doc x @ 415454 @ 3 @ 18.2.1 Special Notes Regarding Explosion ProtectionPos : null /Serie 750 (WAGO-I/O-SYST EM)/Ei ns atz i n Ex-Bereic hen/Bes onder e Hi nweis e hinsichtlich Explosi onssc hutz_2017 @ 29\mod_1491556994025_21.doc x @ 415448 @ @ 1The following warning notices are to be posted in the immediately proximity of theWAGO-I/O-SYSTEM 750 (hereinafter “product”):WARNING – DO NOT REMOVE OR REPLACE FUSED WHILE ENERGIZED!WARNING – DO NOT DISCONNECT WHILE ENERGIZED!WARNING – ONLY DISCONNECT IN A NON-HAZARDOUS AREA!Before using the components, check whether the intended application ispermitted in accordance with the respective printing. Pay attention to anychanges to the printing when replacing components.The product is an open system. As such, the product must only be installed inappropriate enclosures or electrical operation rooms to which the followingapplies:• Can only be opened using a tool or key• Inside pollution degree 1 or 2• In operation, internal air temperature within the range of 0 °C ≤ Ta ≤ +55 °Cor −20 °C ≤ Ta ≤ +60 °C for components with extension number …/025-xxxor −40 °C ≤ Ta ≤ +70 °C for components with extension number …/040-xxx• Minimum degree of protection: min. IP54 (acc. to EN/IEC 60529)• For use in Zone 2 (Gc), compliance with the applicable requirements of thestandards EN/IEC/ABNT NBR IEC 60079-0, -7, -11, -15• For use in Zone 22 (Dc), compliance with the applicable requirements ofthe standards EN/IEC/ABNT NBR IEC 60079-0, -7, -11, -15 and -31• For use in mining (Mb), minimum degree of protection IP64 (acc. EN/IEC60529) and adequate protection acc. EN/IEC/ABNT NBR IEC 60079-0 and-1• Depending on zoning and device category, correct installation andcompliance with requirements must be assessed and certified by a “NotifiedBody” (ExNB) if necessary! |
Related manuals for WAGO 750-602/040-000
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine