1A-11G2.5A OPERATION 1Afc 2c 11015SD03 1015SD041005SD47 1005SD49e 1e 2CHOKEd1d21.16 To StartBefore starting, be sure you read and understand all thesafety and operating instructions in this manual.1. Disconnect all loads from the generator.2. Open fuel valve by moving lever to the right (c 1).Note:If engine is cold, move choke lever to closedposition (d1 ) .If engine is hot, set choke to openposition (d2 ).3. Turn engine switch to “ON” (e1 ).4. Pull starter rope (f) .Note:If the oil level in the engine is low, the enginewill not start. If this happens, check oil level and addoil as needed.5. As engine warms up move choke lever to OPENposition (d2 ).6. Allow engine to warm up a few minutes before attach-ing loads.1.17 To Stop1. Turn off and disconnect all tools and appliancesattached to the generator.2. Turn engine switch to “OFF” (e 2).3. Close fuel valve by moving lever to the left (c 2).Note:To stop engine quickly in an emergency, turnengine switch to "OFF" (e2 ).1.18 Operating Heavy LoadsLimit operations requiring the maximum rated outputof 2500 W to 20 – 30 minutes. For continuous operationdo not exceed the continuous rated output of 2250 W.CAUTION: DO NOT exceed the current limit specifiedon the control panel for any one receptacle.