Portable Generator Repair G 3.7A;G/GS 5.6A;GS 8.5V;GS 9.7Vwc_tx000208gb.fm 656.21 Stator WindingsSee Graphic: wc_gr000949The stator includes the two main power windings and the auxiliarywinding.To check stator windings:6.21.1 Unplug stator connector at control box.6.21.2 Set ohmmeter to lowest scale. Place meter leads on connectorterminals as shown and record resistance values.Check resistance values with those listed inResistance Values.Note:Readings within 2-3 ohms of table values are acceptable.If very high ohm values or "open" then replace stator.Low readings are not normal and may indicate a shortened winding.Stator may have to be replaced.6.21.3 Test for grounded windings by checking for continuity between windingand metal frame.If continuity exists, winding is grounded and stator assembly must bereplaced.Note:Make sure stator is completely disconnected from control panel.The main windings are intentionally grounded to neutral and will give afalse reading.6.21.4 Check for continuity between auxiliary winding and main windings. Ifcontinuity exists, the auxiliary winding has made contact with the mainwinding and stator must be replaced.G 3.7, G 5.6, & GS 5.6GS 8.5 & GS 9.7wc_gr000949