Maintenance RD 1672 wc_tx001076gb.fm4.9 BatterySee Graphic: wc_gr002565Before servicing this machine, make sure the ingnition switch is in theOFF position and that the battery is disconnected. Attach a “DO NOTSTART” sign to the machine. This will notify other personnel that theunit is being serviced and will reduce the chance of someoneinadvertently trying to start the unit.Explosion hazard. Batteries can emit explosive hydrogen gas. Keep allsparks and flames away from the battery. Do not short-circuit batteryposts. Do not touch the machine frame or the negative terminal of thebattery when working on the positive terminal.Battery fluid is poisonous and corrosive. In the event of ingestion orcontact with skin or eyes seek medical attention immediately.Dispose of dead batteries in accordance with local environmentalregulations.To disconnect the battery:4.9.1 Stop the machine and shut down the engine.4.9.2 Place all electrical switches in the OFF position.4.9.3 Disconnect the negative (–) battery cable from the battery.4.9.4 Disconnect the positive (+) battery cable from the battery.To connect the battery:4.9.5 Connect the positive (+) battery cable to the battery.4.9.6 Connect the negative (–) battery cable to the battery.WARNINGWARNING