4SpecificationsGas Supply Requirements- Non CE Only (Australia / New Zealand):- CE Only:Appliance ClassificationCategory: II2H3P (20, 30 / 37).Flue Type: A1.* - The burner operating pressure is to be measured at the manifold test point with two burnersoperating at full setting. The operating pressure is ex-factory set, through the applianceregulator and is not to be adjusted, apart from when carrying out gas conversion, if required.(Refer to the ‘Gas Conversion’ section for details).Gas ConnectionGas supply connection point is located at the rear of the appliance, approximately 130 mm from theright hand side, 32 mm from the rear and 655 mm from the floor (55 mm for bench top –B models)and is reached from beneath the appliance. (Refer to the ‘Dimensions’ section). With the exceptionof the RN8200G-B and RN8203G-B models which are 100 mm from the right hand side, 32 mm fromthe rear and 55 mm from the floor.Connection is ½" BSP male thread (for RN8200G-B and RN8203G-B models).Connection is ¾" BSP male thread (for all other models).Natural Gas (G20) Propane (G31)Open Burner(each)Griddle(each 300mm section)Open Burner(each)Griddle(each 300mm section)Heat Input(nett)Nominal 6.5 kW 5.5 kW 6.5 kW 5.5 kWReduced 1.75 kW 1.85 kW 1.75 kW 1.95 kWGas Rate (nett) Nominal 0.69 m3 /hr 0.58 m3 /hr 0.51 kg/hr 0.43 kg/hrReduced 0.19 m3 /hr 0.20 m3 /hr 0.14 kg/hr 0.15 kg/hrSupply Pressure 20 mbar 30 / 37 mbarBurner Operating Pressure 9.5 mbar (*)Gas Connection See ‘Gas Connection’ information overleaf26 mbar (*)Natural Gas LP Gas (Propane)Input Rate (N.H.G.C.)- each Open Burner 28 MJ/hr(26,540 Btu/hr)28 MJ/hr(26,540 Btu/hr)- each 300 mm Griddle Section 21 MJ/hr(19,900 Btu/hr)21 MJ/hr(19,900 Btu/hr)Supply Pressure 1.13 - 3.40 kPa(4.5” -13.5” w.c.)2.75 - 4.50 kPa(11” -18” w.c.)Burner Operating Pressure 0.95 kPa (*)(3.7” w.c.)2.6 kPa (*)(10.0” w.c.)Gas Connection See ‘Gas Connection’ information overleaf