29Appendix B – How to Re-Flash SG Server ManuallyFirst, make sure that the server is connected to the network switch.1. Download the zip file named SGSUpdater_2.1 Windows.zip from our FTP:ftp://WavesTech:Hr2W2v6x@public.waves.comIf asked for a username / password, use this information:Username: WavesTechPassword: Hr2W2v6x2. Extract the file, inside you will find a file named SGSUpdater_2.1.3. Run the SGSUpdater_2.1 file.4. Plug in the USB flash drive.Please note: this process will erase all the information on the flash drive.5. Click Scan in the SG Server Updater window.6. Select your USB device from the dropdown menu.7. Click Install.8. Connect the USB flash drive to the SG server USB port.9. Reboot the server.10. Launch MultiRack SG and open the SoundGrid Inventory (F2)11. Now you should see the server, its Status might be Incompatible.12. Click on the Update button next to the Server.13. You will be given an option to re-flash the USB or Server.14. Select the SG Server hard drive (SATA DRIVE) and proceed to install.Now the server is up to date.