To prevent electrical shock and/or equipmentdamage, disconnect electric power to system atmain fuse or circuit breaker box until installationis complete.Label all wires prior to disconnection when ser-vicing controls. Wiring errors can cause improperand dangerous operation.Following installation or replacement, followappliance manufacturers’ recommended instal-lation/service instructions to insure proper op-eration.PART NO. 37-1558BReplaces 37-1558-19714Printed in U.S.A.FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLYBEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSEPERSONAL INJURY AND/OR PROPERTY DAMAGE.DESCRIPTIONWHITE-RODGERS5D51-35, -78 & -90Fan & Limit ControlINSTALLATION INSTRUCTIONSThis fan and limit control combines, in one enclosure, afan switch with an adjustable differential which operatesthe blower in a forced warm air furnace and a limit switchwith a fixed differential which automatically shuts off theburner if the furnace temperature exceeds a predeter-mined high point.Operator: Save these instructions for future use!PRECAUTIONSTHIS CONTROL MUST BE INSTALLED BY A QUALI-FIED INSTALLER.All wiring must conform to local and national electricalcodes and ordinances.This control is a precision instrument, and should behandled carefully. Rough handling or distorting compo-nents could cause the control to malfunction.This control has been accurately calibrated at the factory.Any attempt to re-calibrate this control will void the White-Rodgers warranty.Do not use on circuits exceeding specified volt-ages. Higher voltages will damage control andcould cause shock or fire hazard.If in doubt about whether your wiring is millivolt,low or line voltage, have it inspected by a quali-fied heating and air conditioning contractor or alicensed electrician.CAUTION!A summer fan switch is incorporated in this control toprovide a convenient method for manual operation of thefan for air circulation during the summer.WARNING!INSTALLATIONRemoving CoverTo remove cover from control, grasp cover at top andbottom and pull outward. Grasping the cover by its sideswill make removal more difficult.Location1. The bimetal element should not be too close to anyhot surfaces of the heat exchanger. The elementshould always be at least 3“ away from any hotsurfaces unless the position has been determinedacceptable by the furnace manufacturer.2. If this is a new application, please consult the originalequipment manufacturer for proper location.Mounting, For Flush Mounting (Vertical orSloping Surface)1. Insert the element tube into the bonnet and attachcontrol case with #10 screws. (Two screws, diago-nally located, are sufficient.)2. Replace control cover after wiring and making anyadjustments to the settings.WHITE-RODGERS DIVISIONEMERSON ELECTRIC CO.9797 REAVIS RD., ST. LOUIS, MO. 63123-5398(314) 577-1300, FAX (314) 577-15179999 HWY. 48, MARKHAM, ONT. L3P 3J3(905) 475-4653, FAX (905) 475-4625