Phoenix Installationand Operation ManualPG 21 OF 40M0029�09 SEPTEMBER 2017An ongoing program of product improvement mayrequire us to change specifications without notice.WOOD STONE CORPORATION1801 W. Bakerview Rd.Bellingham, WA 98226 USATEL +1.360.650.1111FAX +1.360.650.1166E-MAIL info@woodstone-corp.comwoodstone-corp.comUTILITY CONNECTIONSMake the electrical connection to theterminals in this junction box� Refer to theequipment data plate for correct voltage�Connect the incoming gas supply tothe 3/4 inch FNPT gas inlet�Knockouts are provided on the back of the oven stand for the incoming gas and electrical supplies� If necessary, holes maybe drilled in the back panel for the incoming gas and electrical� Gas and electrical supplies should be routed in such a waythat they do not interfere with the removal of the oven burner, or block the access to the space under the oven for service�The area beneath the burner needs to be kept clear of conduit and piping to allow for removal of the burner for service� Therear panel must be installed for the oven to function properly.A 3/4-inch full-flow gas shut-off valve should be installed on the gas supply near the oven in such a way that it is readilyaccessible�ELECTRICAL CONNECTIONThis appliance must be electrically grounded in accordance with local code, or in the absence of local code, withthe National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable.n Electrical Diagram is provided inside the bottom cover of the Control Box, and at the end of this manual.13. Make utility connectionsat the rear of the controlbox� Gas and electricalconnections must complywith all relevant local andnational codes, and it amanner acceptable to theauthority having jurisdiction�