8An ongoing program of product improvement m ay require u s to changespecications without notice. WS-GFT, Revised April 2015.Doc no: M0053.02info@woodstone-corp.com or visit woodstone-corp.comwood stone corporation1801 w. bakerview rd.bellingham, wa 98226 usatf. 800.988.8103t. 360.650.1111f. 360.650.1166Tandoor Installation and Operation ManualCombustible construction overhangingthe appliance should be protected in amanner acceptable to the authority havingjurisdiction.Install on a noncombustible floor, or one protectedin a manner acceptable to the authority havingjurisdiction, extending 36 inches in all directions.1-inch side clearanceto combustibleconstructionINSTALLATION CLEARANCESThe Wood Stone gas-fired Tandoor must be installed with at least 1-inchside clearance to combustible construction� Install the unit on a non-combustible floor, or one provided with a non-combustible coveringthat extends at least 36-inches in all directions� Any combustibleconstruction above (overhanging) the appliance should be protected ina manner acceptable to the authority having jurisdiction�ENCLOSURESIf the appliance is enclosed, provisions should be made so that it caneasily be removed from the enclosure�VENTINGThe Wood Stone gas-fired Tandoor must be installed under an appropriate NFPA 96 approved Type 1 exhaust hood� Refer to localand/or national codes for hood specification requirements� The hood must be designed for the removal of the combustion productsof gas, as well as the cooking vapors related to the intended use of the oven�Some jurisdictions may require that the Tandoor be interlocked to the hood ventilation system to prevent operation of the appliancewhen the ventilation system is not turned on� If an interlock is required, use an approved gas solenoid (supplied and installed byothers), wired so that the gas supply to the appliance is turned off whenever the ventilation system is turned off�! WARNING: Do not pack required air space (clearance) with insulation or other materials. When non-combustible building materials contact the body of the oven, the clearances to combustibles aretransferred to those non-combustibles.CLEARANCES & VENTINGShaded area must be left unobstructed for criticalcombustion air and easily accessible for removalof the drip/debris pan and operation of the pilotsafety valve. If this area must be covered, thecover should be easily removable and heavilyperforated.INSTALLATION