Questions? Call Wood Stone at 800-578-6836 4MH-RFG-IR Installation and Operation ManualSeptember2006IF THIS APPLIANCE IS NOT PROPERLY INSTALLED A FIRE MAY RESULT.TO REDUCE THE RISK OF FIRE, FOLLOW THESE INSTALLATIONINSTRUCTIONS. A MAJOR CAUSE OF APPLIANCE RELATED FIRES ISFAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TOCOMBUSTIBLE MATERIALS. IT IS OF UTMOST IMPORTANCE THAT THISAPPLIANCE BE INSTALLED ONLY IN ACCORDANCE WITH THESEINSTRUCTIONS.WARNING: Installation and servicing of this product could expose youto glasswool/ceramic fibers as well as Calcium Silicate dust. ALWAYSWEAR RESPIRATORY AND EYE PROTECTION WHEN INSTALLING ORSERVICING THIS APPLIANCE.Please read this entire manual before you install this appliance. Failureto follow instructions may result in property damage, bodily injury oreven death. Contact your local building or fire officials about restrictionsand installation inspection in your area.CLEARANCESa. The Wood Stone MH-RFG-IR should have a minimum 1'’clearance to combustibles from all sides, and 6" clearance tocombustibles from the top (See Figures 1a. and 1b on page 6). Ifbuilding a facade that will contact the appliance, use completely non-combustible materials*. Please note that standard dry-wall (or sheetrock) is considered a combustible.b. Any facade above and/or 6 inches to either side of the appliancedoorway, must be constructed of noncombustible building materials.NOTICE: FOR STUCCO COVERED UNITS, (MODEL NUMBERSENDING IN “S”), 36” CLEARANCE TO COMBUSTIBLE BUILDINGMATERIALS IS REQUIRED*When non-combustible building materials contact the body of the appliance,the clearances to combustibles are transferred to those non-combustibles.INSTALLATION CLEARANCESc. Install this appliance only on a noncombustible floor surface.