Verification of power voltagePRINCESS – Edition: 17.02.2005 51FIELD SERVICE MANUAL12.3 Verification of power voltageThe voltage settings are marked onthe cover plate of the mains transfor-mer. Machines for USA are set to117V. They have a special transfor-mer according to UL standard whichis not adjustable. Jukeboxes “UNI-Pack” are shipped in 230V setting.This is marked on the machine labelinside of the door. If the voltage set-ting is not clear the transformer coverplate has to be removed. The mainsfuse (T3.15A) is located on the leftbottom side inbetween the three ter-minals for the bill acceptor, the exter-nal mains switch and the fluorescentlamps.Loosen the four screws to remove thecover plate (small arrows).ATTENTION! Always remove power plug before opening transformer cover plate. Neverattempt any intervention to these parts unless qualified!The position of the two plug connectors on the transformer terminals 1 to 9 (primary side) indicatesthe current voltage setting. The following combinations are possible:240V = 1 - 9230V = 1 - 8220V = 2 - 9210V = 2 - 8117V = 1 - 6100V = 2 - 6Notice that these settings cannot bemade on machines produced accor-ding to UL standard.NOTE: Never connect the fluorescentsupply to other contact.If you intend to change the power vol-tage for a higher voltage (e.g. from117V to 230V) it is better to use asubtransformer for the fluorescentlamps or change the ballast accordingto the used voltage (e.g. for 230V).NetzsicherungMains Fuse210-240V - T 4A100-117V - F 6ALeuchtstofflampenFluorescent Lamps230V / 117VVerstärkerAmplifierExterner HauptschalterExternal Mains switchSchein-annehmerBill-acceptorAchtungVor A nahme er appe en NetzsteckerziehenarningShock hazar o not openur Beachtung Nur Sicherungen mitgleicher röße un gleichem erterwen en, um Schä en zu ermei enaution To re uce the risk of firereplace onl with same t p an rating fusesNetzspannung50/60 HzMains Voltage50/60 cps240230220210117100Netzsicherung/Mains Fuse210-240V - T3,15A100-117V - F6ADeutsche Wurlitzer GmbH