Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- IMPORTANT SAFETY INSTRUCTIONS
- SPECIAL NOTICES
- PERSONAL PRECAUTIONS
- INTRODUCTION
- UNIT IDENTIFICATION
- CONTROLS, INDICATORS AND COMPONENTS
- Figure 4, AC Side
- Figure 5, Internal Components and Indicators
- Figure 7, DC Side
- INSTALLATION
- QUICK INSTALL
- COMPLETE INSTALL
- Figure 8, Air Flow Intake Location
- Figure 9, AC Input/Output Power Connection
- Figure 10, Warning Label
- Table 2, Minimum Recommended Battery Cable Size vs. Cable Length
- Table 3, Battery Cable To Maximum Breaker/Fuse Size
- Figure 11, Battery to Inverter Cable Connection
- Figure 12, Neutral-To-Ground Bond Switching: No External AC Source Connected
- Figure 13, Neutral-To-Ground Bond Switching: External AC Source Connected
- Figure 15, Multiple Point Ground System
- FUNCTIONAL TEST
- MENU SYSTEM
- USER MENU MAP
- SETUP MENU MAP
- USER MENU
- SETUP MENU
- OPERATION
- Figure 18, Trace™ SW Series Inverter Output Waveform
- POWER VS. EFFICIENCY
- INVERTER CAPACITY VS TEMPERATURE
- OPERATING MODES
- INVERTER MODE
- CHARGER MODE
- Figure 22, BTS (Battery Temperature Sensor)
- Table 4, Charging Setpoints For Common Battery Types
- INVERTER/CHARGER MODE
- GENERATOR SUPPORT MODE
- AUTOMATIC GENERATOR CONTROL MODE
- Figure 23, Two Wire Start Wiring Diagram
- Figure 24, Three Wire Start Wiring Diagram (HONDA Type)
- Figure 26, Relay RY7 and RY8 Sequence
- UTILITY BACKUP MODE
- UTILITY INTERACTIVE MODE
- Figure 28, Selling Power Stored In The Batteries; Hypothetical Time Of Day Operational History
- Figure 29, Utility Interactive Line-Tie System With Battery Backup Flow Diagram
- Figure 30, Overvoltage Protection for Battery
- ENERGY MANAGEMENT MODE
- PEAK LOAD SHAVING MODE
- LOW BATTERY TRANSFER (LBX) MODE
- USING MULTIPLE INVERTERS
- TECHNICAL INFORMATION
- BATTERY SIZING
- BATTERY BANK SIZING
- BATTERY CARE AND MAINTENANCE
- Table 7, Battery State of Charge Voltage
- BATTERY INSTALLATION
- BATTERY HOOK-UP CONFIGURATIONS
- Figure 33, Parallel Configuration: 12-Volt Battery Wiring
- Figure 34, Series-Parallel Configuration: 6-Volt Battery Wiring
- BATTERY CABLE INDUCTANCE
- APPLICATIONS
- TROUBLESHOOTING GUIDE
- INVERTER/CHARGER TERMINOLOGY
- Figure 36, AC Waveforms
- SPECIFICATIONS AND FEATURES (60 Hz Models)
- SPECIFICATIONS AND FEATURES (50 Hz Models)
- DIMENSIONS
- INSTALLATION DIAGRAMS
- Figure 39, Installation Diagram, 240 VAC, 3 Wire, Grid Connected, Generator Backup
- USER SETTINGS WORKSHEETS
- APPENDIX
- OTHER PRODUCTS
- REFERENCE TABLES AND GRAPHS
- Figure 40, AWG Wire Size
- Table 13, Recommended Minimum AC Wire Sizes (75 C)
- STORAGE CHECKLIST
- WARRANTY/REPAIR INFORMATION
- WARRANTY OR REPAIR SERVICE REQUIRED
- INDEX
|
TECHNICAL INFORMATIONPage118 2001 Xantrex Technology, Inc.5916 - 195th Street N. E.Arlington, WA 98223Telephone: 360/435-8826Fax: 360/435-2229www.traceengineering.comSW Series Inverter/ChargerPart No. 2031-5Rev. C: February 2001SPECIFICATIONS AND FEATURES (60 Hz Models)Note: All specifications are subject to change without notice.MODEL SW2512 SW4024 SW4048 SW5548 SW4024K SW4048K SW4024WGeneral SpecificationsNominal DC Input Voltage 12 Vdc 24 Vdc 48 Vdc 48 Vdc 24 Vdc 48 Vdc 24 VdcAC Output Voltage (RMS) 120 vac 120 vac 120 vac 120 vac 105 vac 105 vac 220 vacNominal Frequency 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 HzContinuous Power @ 20°C 2500 VA 4000 VA 4000 VA 5500 VA 4000 VA 4000 VA 4000 VAContinuous Output (@ 25°C) 21 amps AC 33 amps AC 33 amps AC 46 amps AC 38 amps AC 38 amps AC 18 amps ACMaximum Output (RMS) 60 amps AC 78 amps AC 78 amps AC 78 amps AC 78 amps AC 78 amps AC 39 amps ACEfficiency (peak) 90% 94% 95% 96% 94% 95% 94%Automatic Transfer Relay 60 amps AC 60 amps AC 60 amps AC 60 amps AC 60 amps AC 60 amps AC 30 amps ACMaximum Charging Rate 150 amps DC 120 amps DC 60 amps DC 75 amps DC 120 amps DC 60 amps DC 120 amps DCCharger Regulation Method 3 stage 3 stage 3 stage 3 stage 3 stage 3 stage 3 stageDC Input RequirementsSearch Mode 0.08 A (1 W) 0.04 A (1 W) 0.025 A (1 W) 0.04 A (1 W) 0.04 A (1 W) 0.025 A (1 W) 0.04 A (1 W)On Mode (no load - idle) 1.0 A (12 W) 0.66 A (16 W) 0.33 A (16 W) 0.40 A (20 W) 0.66 A (16 W) 0.33 A (16 W) 0.66 A (16W)At Full Rated Power 275 amps 200 amps 100 amps 137 amps 200 amps 100 amps 200 ampsShort Circuited Output 700 amps 360 amps 180 amps 180 amps 360 amps 180 amps 360 ampsInput Voltage Range 11.8 to 16.5 Vdc 22 to 33 Vdc 44 to 66 Vdc 44 to 66 Vdc 22 to 33 Vdc 44 to 66 Vdc 22 to 33 VdcAC Output CharacteristicsAC Output Waveform Sine wave, 34 to 52 steps per cycleVoltage Regulation ± 2%Total Harmonic Distortion 3 to 5% (stand alone operation)Power Factor Allowed -1 to 1Frequency Regulation ± 0.04% (crystal regulated)Load Sensing Range 16 to 240 WattsStandard FeaturesControl Panel Built-in 2 line back-lit alphanumeric liquid crystal display with eight LED status indicatorsLow Battery Protection Adjustable low battery cut out and cut in with current compensationBattery Temperature Sensor 15 foot plug in battery temperature sensor with phone type jack (can be extended)Auto Generator Control system Automatic generator control system for two and three wire start generators (no glow-plug control)Auxiliary Relays Three user adjustable voltage controlled signal relays for control of loads or charging sourcesFan Cooling Variable speed brushless DC fansOptionsRemote Control Panel SWRC SWRC SWRC SWRC SWRC SWRC SWRCStacking Interface for 2X power(* requires two inverters)SWI *(120/240 vac)SWI*(120/240 vac)SWI *(120/240 vac)SWI *(120/240 vac)No No NoConduit Box SWCB SWCB SWCB SWCB SWCB SWCB SWCBEnvironmental LimitationsEnclosure Type Indoor, ventilated, steel chassis with powdercoat finishSpecified Temp Range 32°F to 104°F (0°C to +40°C) (output will meet specified tolerances)Allowed Temperature Range -40°F to 140°F (-40°C to +60°C) (output may not meet specified tolerances)Non-operating Temperature -67°F to 284°F (-55°C to +75°C)Altitude Limit Operating 15,000 feet (5000 meters)Altitude Limit Non-operating 50,000 feet (16,000 meters)Dimensions - Inverter Only 15” (38 cm) high, 22.5” (57 cm) wide, 9” (23 cm) deep (when wall mounted)Dimensions - Shipping 20.5” (52 cm), 27” (69 cm), 15.5” (40 cm)Mounting Wall or Shelf MountWeight - Inverter Only 90 lb (42 kg ) 105 lb (48 kg) 105 lb (48 kg) 136 lb (63 kg ) 105 lb (48 kg) 105 lb (48 kg) 105 lb (48 kg)Weight - Shipping 96 lb (44 kg) 111 lb (50 kg) 111 lb (50 kg) 143 lb (65 kg) 111 lb (50 kg) 111 lb (50 kg) 111 lb (50 kg)
PreviousNext |