Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- IMPORTANT SAFETY INSTRUCTIONS
- SPECIAL NOTICES
- PERSONAL PRECAUTIONS
- INTRODUCTION
- UNIT IDENTIFICATION
- CONTROLS, INDICATORS AND COMPONENTS
- Figure 4, AC Side
- Figure 5, Internal Components and Indicators
- Figure 7, DC Side
- INSTALLATION
- QUICK INSTALL
- COMPLETE INSTALL
- Figure 8, Air Flow Intake Location
- Figure 9, AC Input/Output Power Connection
- Figure 10, Warning Label
- Table 2, Minimum Recommended Battery Cable Size vs. Cable Length
- Table 3, Battery Cable To Maximum Breaker/Fuse Size
- Figure 11, Battery to Inverter Cable Connection
- Figure 12, Neutral-To-Ground Bond Switching: No External AC Source Connected
- Figure 13, Neutral-To-Ground Bond Switching: External AC Source Connected
- Figure 15, Multiple Point Ground System
- FUNCTIONAL TEST
- MENU SYSTEM
- USER MENU MAP
- SETUP MENU MAP
- USER MENU
- SETUP MENU
- OPERATION
- Figure 18, Trace™ SW Series Inverter Output Waveform
- POWER VS. EFFICIENCY
- INVERTER CAPACITY VS TEMPERATURE
- OPERATING MODES
- INVERTER MODE
- CHARGER MODE
- Figure 22, BTS (Battery Temperature Sensor)
- Table 4, Charging Setpoints For Common Battery Types
- INVERTER/CHARGER MODE
- GENERATOR SUPPORT MODE
- AUTOMATIC GENERATOR CONTROL MODE
- Figure 23, Two Wire Start Wiring Diagram
- Figure 24, Three Wire Start Wiring Diagram (HONDA Type)
- Figure 26, Relay RY7 and RY8 Sequence
- UTILITY BACKUP MODE
- UTILITY INTERACTIVE MODE
- Figure 28, Selling Power Stored In The Batteries; Hypothetical Time Of Day Operational History
- Figure 29, Utility Interactive Line-Tie System With Battery Backup Flow Diagram
- Figure 30, Overvoltage Protection for Battery
- ENERGY MANAGEMENT MODE
- PEAK LOAD SHAVING MODE
- LOW BATTERY TRANSFER (LBX) MODE
- USING MULTIPLE INVERTERS
- TECHNICAL INFORMATION
- BATTERY SIZING
- BATTERY BANK SIZING
- BATTERY CARE AND MAINTENANCE
- Table 7, Battery State of Charge Voltage
- BATTERY INSTALLATION
- BATTERY HOOK-UP CONFIGURATIONS
- Figure 33, Parallel Configuration: 12-Volt Battery Wiring
- Figure 34, Series-Parallel Configuration: 6-Volt Battery Wiring
- BATTERY CABLE INDUCTANCE
- APPLICATIONS
- TROUBLESHOOTING GUIDE
- INVERTER/CHARGER TERMINOLOGY
- Figure 36, AC Waveforms
- SPECIFICATIONS AND FEATURES (60 Hz Models)
- SPECIFICATIONS AND FEATURES (50 Hz Models)
- DIMENSIONS
- INSTALLATION DIAGRAMS
- Figure 39, Installation Diagram, 240 VAC, 3 Wire, Grid Connected, Generator Backup
- USER SETTINGS WORKSHEETS
- APPENDIX
- OTHER PRODUCTS
- REFERENCE TABLES AND GRAPHS
- Figure 40, AWG Wire Size
- Table 13, Recommended Minimum AC Wire Sizes (75 C)
- STORAGE CHECKLIST
- WARRANTY/REPAIR INFORMATION
- WARRANTY OR REPAIR SERVICE REQUIRED
- INDEX
|
MENU SYSTEMPage34 2001 Xantrex Technology, Inc.5916 - 195th Street N. E.Arlington, WA 98223Telephone: 360/435-8826Fax: 360/435-2229www.traceengineering.comSW Series Inverter/ChargerPart No. 2031-5Rev. C: February 2001USER MENU MAPMenu Heading The values shown are the factory default values forModel SW2512.Menu ItemSetpointSee the USER and SETUP menu item descriptionsfor default values for other models.InformationInverter Mode1Generator Mode2TraceEngineering 3Meters4Error Causes5Time of Day00:00:00 6Set InverterOFF SRCH ON CHGSet GeneratorOFF AUTO ON EQPress reset nowfor defaultsInverter/chargerAmps AC 00Over CurrentNOSet Clock hour00:00:00CHG avail. Onlyin FLT mode.Gen under/overspeed NORevision 4.01 Input amps AC00Transformerovertemp NOSet Clock minute00:00:00Press red orsetpoint buttonGenerator starterror NO5916 195th St NEArlington, WALoadamps AC 00Heatsinkovertemp NOSet Clock second00to move.Move cursor toGenerator syncerror NO98223 USA Battery actualvolts DC 12.6High Batteryvoltage NOInverter OFF toresetOverCurrentGen max run timeerror NOPh 360-435-8826Fax 360-435-2229Battery TempCompvolts DC 12.6Low Batteryvoltage NOLoad Amp StartReady NOInvertervolts AC 00Inverter breakertripped NOGenerator Timer7Voltage StartReady NOGrid (AC1)volts AC 00AC source wiredto output NOStart QuietTime h:m 08:00Exercise StartReady NOGenerator (AC2)volts AC 00External error(stacked) NOEnd QuietTime h:m 08:00Move cursor toGEN OFF to resetRead FrequencyHertz 60Generator starterror NOGen doesn’t runDuring quietGenerator error. AC1 & AC2 voltsvalid only whenGenerator syncerror NOtime unless battvolts is less.If no start in 5trys then error.inverter syncedto that input.Gen max run timeerror NOthan LBCO voltsfor 30 seconds.If Gen starts &runs for 5 minBatt volt actualis used forGen under/overspeed NOTo defeat timersset start = end.then stops theinverter willLBCO,HBCO,LBX,LBCI,sell volts,Inverter breakertripped NOIf exercise dayset to 1 thennot attemptrestart untiland gen starting gen will alwaysstart @ endquietgen auto startconditions areBatt volt tempcomp is used,again satisfied. for float, bulk, eq& aux relaysIf Gen runs forMore than maxRun time thenError.Under/Over speedWill cause aSync error in 10minutesEnd User Menu8MENU HEADINGSMENU ITEMSPush buttons onControl Panel