Optional Oversized High Capacity Feeder (OHCF)Section SpecificationNominal Voltage 100-240 VAC, single phase (+6% to -10%)Amperage 15Cycles (single phase) 50/60 HZXerox Receptacle Part No. 600S3704Receptacle NEMA Part No. 5-15RPower Cord Length 10 feet/3 metersReceptacle Diagram(XNAonly, All others: Flying leads)Power 60 W maximumNOTE: Surge protection for the OHCF is strongly recommended and is the responsibility of thecustomer.The following illustration shows the space requirements and service space envelope for the Xerox4595 with the optional Finisher/Folder and OHCF installed. For other configurations, consult theModule Dimensions chart.Note 1: The dimensions shown are absolute minimums.Note 2: 78" (1981 mm) minimum height clearance in service envelope.Note 3: Location of left rear corner of main processor should be marked with tape for delivery personnel.(See diagram above)Note 4: If there is no HCF or OHCF attached, then the Multi-Sheet Inserter, in the closed position (3.3”/83mm), must be calculated in the space requirements.Service/ Operational Space Moveable Installation1 Stationary InstallationRear of Main Processor/System 10”/254 mm 24”/610 mmFront of Main Processor 54”/1372 mm 54”/1372 mmFront of HCF and Finisher/Folder 38”/965 mm 38”/965 mmFront of OHCF and Finisher/ Folder 38”/965 mm 38”/965 mmSide of System 24”/610 mm 24”/610 mmHeight of System 78”/1981 mm 78”/1981 mm1 Moveable installation dimensions can be used when the system is installed on a hard surface(concrete, wood, and/or with a mobility plate).18