Adjustments and Calibrations 6-7RegiCon #1 Fine Skew AdjustmentThis process uses sensors to examine the RegiCon image on the belt and report whatadjustments need to be made. A side effect of this test is that horizontal and verticalalignments are automatically done (if the test passed).The data output presents the skew screw adjustment values (some number of "clicks"of the screw, either CW or CCW direction). Values less than 5 or so are "noise" andshould not need to be adjusted.1. From the Hidden Service menu, highlight the RegiCon Setup Cycle menuand press OK.2. The first time any RegiCon test is requested, the pages used to perform the testmust be created, so there is a short delay. During this time the front panel displays“Processing Data - Please Wait”3. Highlight Do #1 Fine Skew Setup and press OK. The front panel nowdisplays: Testing - Please Wait.4. Wait until the test results are displayed as follows:NoteOnly 5 lines will be displayed at a time under the Information header. Usethe arrow buttons to scroll down or up as required to see the rest of the data.NoteIf the block counts are not the same number as presented here, the printer hasa print-quality problem. See "Streaks in Direction of Paper Travel" onpage 5-17 to resolve the print-quality problems before proceeding furtherwith RegiCon.5. If an adjustment is needed, adjust by the amounts displayed on the front paneluntil all clicks displayed are 5 or less.NoteIf RegiCon #1 Fine Skew test fails, see "RegiCon #4 Coarse SkewAdjustment" on page 6-10.Fine Skew SetupYellow 1 Click CWMin B Blocks: 4Min A Blocks: 24PassedMagenta 7 Clicks CCWCyan 7 Clicks CWBlack 7 Clicks CCW