Revision 1.1 WebSwitch™ Users Manual3.5.2 Email Notification SetupEmail notification requires the following fields are properly set. See Section 2 for a description of eachfield.Network Tab:━ IP Address━ Subnet Mask━ Gateway━ Preferred DNS Server (this is required if Mail Server is entered by name and not by IP address)━ Mail Server (SMTP)━ User Name (If Required)━ Password (If Required)━ Return Email━ Email 1 (additional Email addresses may be entered)Once the settings under the Network tab are entered correctly, an email trigger(s) must be configured.An email trigger can be generated within a BASIC script (See Appendix G for information about BASICscripts), or can be explicitly defined for each outlet, input, and sensor (under Outlets, Inputs, andSensors tabs). For each outlet, input, and sensor trigger, the “Email Option' field should be set to theappropriate trigger. Finally, the appropriate email addresses should be selected for each outlet, input,and sensor trigger by checking the box next to the desired email address under the Outlets, Inputs, andSensors tabs.Once the email settings are entered, the email functionality can be tested by entering the followingcommand:http://192.168.1.2/state.xml?testEmail=1This will cause an email message to be sent immediately. If the message doesn't get through, thesystem log file may have some clues to assist in diagnosing the problemhttp://192.168.1.2/syslog.txtXytronix Research & Design, Inc. 82