Drive Model Terminal Recomm. Gaugemm2 (AWG, kcmil)Wire Rangemm2 (AWG, kcmil)ScrewSizeTightening TorqueN·m (lb.in.)5A00275A0032R/L1, S/L2, T/L3 16(6)16 to 25(6 to 4)M6 5.4 to 6.0(47.8 to 53.1)U/T1, V/T2, W/T3 16(6)16 to 25(6 to 4)⊖, ⊕1, ⊕2 – 16 to 25(6 to 4)B1, B2 – 6.0 to 10(10 to 8) M5 2.7 to 3.0(23.9 to 26.6)16(6)10 to 16(10 to 6) M6 5.4 to 6.0(47.8 to 53.1)5A0041R/L1, S/L2, T/L3 16(6)6.0 to 25(10 to 3)M8 9.0 to 11(79.7 to 97.4)U/T1, V/T2, W/T3 16(6)6.0 to 25(10 to 3)⊖, ⊕1 – (6 to 1)B1, B2 – 4.0 to 25(12 to 3)16(6)10 to 16(6)5A0052R/L1, S/L2, T/L3 25(4)6.0 to 25(10 to 3)M8 9.0 to 11(79.7 to 97.4)U/T1, V/T2, W/T3 16(6)6.0 to 25(10 to 3)⊖, ⊕1 – 16 to 35(6 to 1)B1, B2 – 10 to 25(8 to 3)16(6)10 to 16(6)5A0062R/L1, S/L2, T/L3 25(4)6.0 to 95(10 to 4/0)M10 18 to 23(159 to 204)U/T1, V/T2, W/T3 25(4)6.0 to 95(10 to 4/0)⊖, ⊕1 – 25 to 95(4 to 4/0)⊕3 – 16 to 95(6 to 4/0)25(4)25(4)5A0077R/L1, S/L2, T/L3 25(3)6.0 to 95(10 to 4/0)M10 18 to 23(159 to 204)U/T1, V/T2, W/T3 25(3)6.0 to 95(10 to 4/0)⊖, ⊕1 – 25 to 95(3 to 4/0)⊕3 – 16 to 95(6 to 4/0)25(4)25(4)5A0099R/L1, S/L2, T/L3 70(1/0)6.0 to 95(10 to 4/0)M10 18 to 23(159 to 204)U/T1, V/T2, W/T3 50(1)6.0 to 95(10 to 4/0)⊖, ⊕1 – 35 to 95(2 to 4/0)⊕3 – 25 to 95(4 to 4/0)25(4)25(4)i.4 Electrical InstallationYASKAWA TOEP YAIP1W 02E YASKAWA AC Drive - iQpump1000 Installation & Start-up Guide 33