16 TOEP C710606 27 J1000 Quick Start Guide4 Keypad Operation4 Keypad Operation LED Operator and KeysThe LED operator is used to program the drive, to start/stop it, and to display fault information. The LEDs indi-cate the drive status. Keys and FunctionsDisplay Name FunctionData Display Area Displays the frequency reference, parameter number, etc.ESC Key Returns to the previous menu.RESET Key Moves the cursor to the right.Resets a fault.RUN KeyStarts the drive in the LOCAL mode. The Run LED• is on, when the drive is operating the motor.• flashes during deceleration to stop or when the frequency reference is 0.• flashes quickly the drive is disabled by a DI, the drive was stopped using a faststop DI or a run command was active during power up.Up Arrow Key Scrolls up to select parameter numbers, setting values, etc.Down Arrow Key Scrolls down to select parameter numbers, setting values, etc.STOP Key Stops the drive.ENTER Key Selects modes, parameters and is used to store settings.LO/RE SelectionKeySwitches drive control between the operator (LOCAL) and the control circuitterminals (REMOTE). The LED is on when the drive is in the LOCAL mode(operation from keypad).ALM LED Light Flashing: The drive is in an alarm state.On: The drive is in a fault state and the output is stopped.REV LED Light On: The motor rotation direction is reverse.Off: The motor rotation direction is forward.DRV LED Light On: The drive is ready to operate the motor.Off: The drive is in the Verify, Setup, Parameter Setting mode.FOUT LED Light On: The output frequency is displayed on the data screen.Off: Anything else than the output frequency is displayed on the data screen.STOPRUNSTOPALMREVDRVFOUT