22 TOEP C710606 27 J1000 Quick Start Guide6 Parameter Table6 Parameter TableThis parameter table shows the most impor-tant parameters. Default settings are boldtype. Refer to the instruction manual for acomplete list of parameters.Par. Name DescriptionInitialization ParametersA1-01AccessLevelSelectionSelects which parameters areaccessible via the digital operator.0:Operation only2:Advanced Access LevelA1-03 InitializeParametersResets all parameters to default.(returns to 0 after initialization)0000: No Initialize2220: 2-Wire Initialization3330: 3-Wire InitializationOperation Mode Selectionb1-01FrequencyReferenceSelection0:Operator - d1- values1:Analog input A12:Serial Comm.option3:Potentiometer Optionb1-02RunCommandSelection0:Operator - RUN and STOP keys1:Terminals - Digital Inputs2:Serial Comm.optionb1-03StoppingMethodSelectionSelects the stopping method whenthe run command is removed.0:Ramp to Stop1:Coast to Stopb1-04ReverseOperationSelection0:Reverse enabled1:Reverse prohibitedb1-14 Phase OrderSelectionSwitches the output phase order.0:Standard1:Switch phase orderDC Injection Brakingb2-02DCInjectionBrakingCurrentSets the DC Injection Braking cur-rent as a percentage of the driverated current.b2-03DC Inj.BrakingTime/DCExcitationTime atStartSets the time of DC Injection Brak-ing at start in units of 0.01 seconds.Disabled when set to 0.00 seconds.b2-04DC Inj.BrakingTime atStopSets the DC Injection Braking timeat stop. Disabled when set to 0.00seconds.Acceleration/ DecelerationC1-01 AccelTime 1Sets the acceleration time 1 from 0to the max. output frequency.C1-02 DecelTime 1Sets the deceleration time 1 fromthe max. output frequency to 0.C2-01 S-Curve 1 S-curve at acceleration start.C2-02 S-Curve 2 S-curve at acceleration end.C2-03 S-Curve 3 S-curve at deceleration start.C2-04 S-Curve 4 S-curve at deceleration end.Slip CompensationC3-01Slip Com-pensationGain• Increase if the speed is lower thanthe frequency reference• Decrease if the speed is higherthan the frequency reference.C3-02Slip Com-pensationDelay Time• Decrease the setting when the slipcompensation is too slow.• Increase the setting when thespeed is not stable.Torque CompensationC4-01TorqueCompensa-tion Gain• Increase this setting when thetorque response is slow• Decrease this setting when speed/torque oscillations occur.Duty Mode and Carrier FrequencyC6-01Normal/Heavy DutySelection0: Heavy Duty (HD)Constant torque applications1:Normal Duty (ND)Variable torque applicationPar. Name Description