8 - 40– +ELECELECTRICAL CONTROL SYSTEM• Within 4 seconds, press the followingswitches on the CO, diagnosis switch boxin the order indicated to enter the COemission adjustment mode.6 MODE switch = 17 UP switch = 28 DOWN switch = 31 → 2 → 3 → 1 → 2 → 3 → 1 → 2 → 3 → 1 →2 → 3The warning light flashes for 1.4 secondswhen the unit has entered the CO emissionadjustment mode. During this time, thetachometer displays the engine idlingspeed.NOTE:Turn the main switch to “OFF” to cancel theCO emission adjustment mode.• According to the following table, selectthe cylinder to be adjusted by holdingdown the MODE switch while pressingeither the UP switch or the DOWN switch.• Release the MODE switch to start the COemission adjustment for the selected cyl-inder. The warning light flashes onceevery 0.5 second and the tachometer dis-plays the engine speed.• While watching the CO tester, press theUP switch or DOWN switch to adjust theCO emission.NOTE:• If the UP switch is pressed when the COemission has reached its maximum or ifthe DOWN switch is pressed when the COemission has reached its minimum, thewarning light flashes once every 0.16 sec-ond.Tachometer display Selected cylinder1,000 r/min Cylinder #12,000 r/min Cylinder #23,000 r/min Cylinder #34,000 r/min Cylinder #4Press the UP switch Increase CO emis-sionPress the DOWNswitchDecrease CO emis-sionOfrecido por www.electromanuales.com