5120410-XIM-B-0216Johnson Controls Unitary Products 21Table 13: Electrical DataVoltage11. Unit voltage limitations: minimum utilization 342 volts, maximum utilization 457 volts.Compressors OD FanMotorsSupplyBlower MotorFLAPwr ExhMotor Electric HeaterModel No.ActualkWHeaterAmpsMin. CircuitAmpacity(Amps)MCA w/PowerExhaust(Amps)Max Fuse22. Maximum HACR breaker of the same amp size is acceptable.Size (Amps)Max Fuse Sizew/PowerExhaust (Amps)RLAea.LRAea.FLAea.2 HP(1.5 kW) FLA 2 HP(1.5 kW)2 HP(1.5 kW)2 HP(1.5 kW)2 HP(1.5 kW)380 8.0 53 1.1 5.2 2.2 None - - 25.4 27.6 30 352TP0454185033. Field Installed Kit Only.11.3 17.2 28.0 30.8 30 35415 8.0 53 1.1 5.2 2.2 None - - 25.4 27.6 30 352TP045418503 13.5 18.8 30.0 32.8 30 35Voltage1CompressorsODFanMotorsSupply BlowerMotor FLAPwr ExhMotor ElectricHeaterModel No.ActualkWHeaterAmpsMin. CircuitAmpacity(Amps)MCAw/PowerExhaust(Amps)Max Fuse2Size (Amps)Max Fuse Sizew/PowerExhaust(Amps)RLAea.LRAea.FLAea.2 HP(1.5 kW)4 HP(3 kW) FLA 2 HP(1.5 kW)4 HP(3 kW)2 HP(1.5 kW)4 HP(3 kW)2 HP(1.5 kW)4 HP(3 kW)2 HP(1.5kW)4 HP(3kW)380 9.6 80 1.1 5.2 7.5 2.2None - - 29.0 31.3 31.2 33.5 35 40 40 402TP04521850 11.3 17.2 29.0 31.3 31.2 33.5 35 40 40 402TP04522450 15.0 22.8 35.0 37.9 37.7 40.6 35 40 40 452TP04523650 21.3 32.4 47.0 49.8 49.7 52.6 50 50 50 602TP04525450 33.8 51.4 70.7 73.6 73.4 76.3 80 80 80 80415 9.6 80 1.1 5.2 7.5 2.2None - - 29.0 31.3 31.2 33.5 35 40 40 402TP04521850 13.5 18.8 30.0 32.9 32.7 35.6 35 40 40 402TP04522450 17.9 24.9 37.6 40.5 40.4 43.3 40 45 45 452TP04523650 25.4 35.3 50.7 53.5 53.4 56.3 60 60 60 602TP04525450 40.4 56.2 76.8 79.6 79.5 82.4 80 80 80 90Electrical data 12-1/2 tonVoltage1CompressorsODFanMotorsSupply AirBlowerMotor FLAPwr ExhMotor ElectricHeaterModel No.ActualkWHeaterAmpsMin. Cir-cuitAmpacity(Amps)MCAw/PowerExhaust(Amps)MaxFuse2Size(Amps)Max FuseSizew/PowerExhaust(Amps)RLAea.LRAea.FLAea. 4 HP (3 kW) FLA 4 HP(3 kW)4 HP(3 kW)4 HP(3 kW)4 HP(3 kW)380 12.0 91 1.1 7.5 2.2None - - 36.7 38.9 45 502TP04521850 11.3 17.2 36.7 38.9 45 502TP04522450 15.0 22.8 37.9 40.6 45 502TP04523650 21.3 32.4 49.8 52.6 50 602TP04525450 33.8 51.4 73.6 76.3 80 80415 12.0 101 1.1 7.5 2.2None - - 36.7 38.9 45 502TP04521850 13.5 18.8 36.7 38.9 45 502TP04522450 17.9 24.9 40.5 43.3 45 502TP04523650 25.4 35.3 53.5 56.3 60 602TP04525450 40.4 56.2 79.6 82.4 80 901. Unit voltage limitations: minimum utilization 342 volts, maximum utilization 457 volts.2. Maximum HACR breaker of the same amp size is acceptable.Electrical data 7-1/2 tonElectrical data 10 ton1. Unit voltage limitations: minimum utilization 342 volts, maximum utilization 457 volts.2. Maximum HACR breaker of the same amp size is acceptable.