5120410-XIM-B-0216Johnson Controls Unitary Products 5NomenclatureD C 090 N10 A 7 A AA 7 0 1 2 4 AD = A/C, Single Pkg., R-407CProduct Category7 = Seventh GenerationProduct GenerationC00 = Cooling Only. No heat installedHeat Type and Nominal Heat CapacityN10 = 100 MBH Output Aluminized SteelN15 = 150 MBH Output Aluminized SteelS10 = 100 MBH Output Stainless SteelS15 = 150 MBH Output Stainless SteelE09 = 9 KWE18 = 18 KWE24 = 24 KWE36 = 36 KWE54 = 54 KWGas Heat OptionsElectric Heat Options*Nominal Cooling Capacity090 = 7.5 Ton120 = 10.0 Ton150 = 12.5 TonProduct IdentifierC = 9.0 EER A/CVoltage7 = 380/415-3-50Product StyleA = Style AB = Style BC = Style CA = No Options InstalledInstallation OptionsB = Option 1C = Option 2D = Options 1 & 2E = Option 3F = Option 4G = Options 1 & 3H = Options 1 & 4J = Options 1, 2 & 3K = Options 1, 2, & 4L = Options 1,3 & 4M = Options 1, 2, 3, & 4N = Options 2 & 3P = Options 2 & 4Q = Options 2, 3, & 4R = Options 3 & 4S = Option 5T = Options 1 & 5U = Options 1, 3, & 5V = Options 1, 4, & 5W = Options 1, 3, 4, & 5X = Options 3 & 5Y = Options 4 & 5Z = Options 3, 4 & 51 = Disconnect2 = Non-Pwr'd Conv. Outlet3 = Smoke Detector S.A.4 = Smoke Detector R.A.5 = Pwr'd Conv. OutletOptionsSS Drain PanConfiguration Options (not required for all units)These four digits will not be assigned until a quote is requested, or an order placed.Honeywell Controller, DFS, APSCPC Controller, DFS, APSSimplicity®Smart Equipment w/Comm Card (BACnet, N2, Mod-Bus)2" Pleated filtersBAS Ready Unit with EconomizerShipping BagAny Combination of Additional Options that Don’t Have an Option Code Pre-assignedAA = NoneAB = Phase MonitorAC = Coil GuardAD = Dirty Filter SwitchAE = Phase Monitor & Coil GuardAF = Phase Monitor & Dirty Filter SwitchAG = Coil Guard & Dirty Filter SwitchAH = Phase Monitor, Coil Guard & Dirty Filter SwitchAdditional OptionsRC = Coil Guard, Shipping Bag & American FlagEA = E-coat Condenser CoilEJ = E-coat Evaporator CoilES = E-coat Cond & Evap Coils7.5-12.5 Ton York ® Model Number NomenclatureZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will belocated in digits 15-18.*DC090 No Factory Electric Heat OptionsAirflowA = Std. MotorD = Std. Motor/Motorized Damper (Downflow Only)H = Std Motor/Low Leak Econ/Barometric Relief (Downflow& Horizontal End Return Only)J = Std Motor/Low Leak Econ/Power Exhaust (Downflow& Horizontal End Return Only)N = Hi StaticR = Hi Static/Motorized Damper (Downflow Only)V = Hi Static Mtr/Low Leak Econ/Barometric Relief(Downflow & Horizontal End Return Only)W = Hi Static Mtr/Low Leak Econ/Power Exhaust(Downflow & Horizontal End Return Only)