by johnson controls6Installation InstructionsInspectionUpon reception, inspect the equipment andnotify both the carrier and the insurancecompany, in writing, of any possible damage.Environmental protectionEliminate packing in accordancewith the regulations in force onenvironmental conservation.During installation and maintenance, keepin mind that HFC-410A and oil POE areused.Contains greenhouse effect fluoridedgas covered by the Kyoto protocol.For the type of gas and quantity per system,see the identification plate. GWP (GlobalWarming Potential): 2088.TransportationTransport to final place of installation alwayswith the symbols in vertical position.ClearancesLeave clearances for maintenance access,changing air filters and air discharge. (Fig.1).Installation of indoor unitThese units can be installed either verticallyon the floor, horizontally beneath the ceilingor vertically on a wall. (Fig. 2).FasteningRemove side panels and air intake grill, asshown in drawings. (Figs. 3, 4 & 5).Fasten mounting supports to the wall orceiling. For ceiling units, installation neara wall makes tubing layout easier. Use theperforations in the unit casing to orient thedirection of the tubing.Fit the unit onto the mounting supports.Make sure the unit is levelled so condensedwater drain is carried out correctly.Condensed water drainThe unit drain pipe is flexible and adjusts tovarious layouts. The drain line must includea U-shaped elbow siphon. Connect a plastichose with a 16 mm. outer diameter (Fig.6).Checking drainMake sure water evacuation is carried outcorrectly. (Fig. 7).Electrical connectionsSo installation may be correct, the unitmust be grounded.Wiring should follow, at all times, establishednational regulations.Also check the tension limits. Make sureelectric connections are tight so as to avoidoverheating and failure risks.Cable sectionSizes 0912 18 24 30 36, 42, 48 (1ph)36, 42, 48 (3ph) 60Power supplymm23 x2,5 3 x 4 3 x 6 3 x 6 (1ph)5 x 4 (3ph) 5 x 4Interconnection(ind./out.) 2 x 0,25Fuse(D Curve) A 13 20 25 25 16 20 20 20Prior to final approval of theinstallationCheck:- The voltage is always between198-254 V.- The power supply cable sectionis, at least, that recommended.- Condensed water drainageis carried out correctly, andthere are no leaks in the watercircuit.- Operating instructions havebeen given to the user.- Information has been given onthe need to clean the air filterperiodically.- Maintenance instructions havebeen given, or a contract hasbeen made for periodicalservicing.WiringGBATTENTIONYour product is marked with this symbol. This means that at the end of its service life it should not be mixedwith other non-classified household waste. Therefore, disposal should be carried out in compliance with thecorresponding local and national regulations, in a correct and environment-friendly manner.The dismantling of the air conditioning unit, as well as the processing of refrigerant, oil and other components,should be carried out by a qualified technician and in compliance with the applicable legislation.Contact your local authorities for further informationAll data and dimensions are subject to change without prior notice.EOKC 09, 12, 18, 24, 30, 36, 42, 48 DEOKC 36, 42, 48, 60 DFig. 8OUTDOOR UNITOUTDOOR UNITINDOOR UNITINDOOR UNIT