036-21137-003 Rev. A (1102)Unitary Products Group 19Multipliers for determining the performance with other indoor sections.NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above thelisted temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.COOLING PERFORMANCE DATAAIR CONDITIONER MODEL NO. H2RC048S06INDOOR COIL MODEL NO. G1FA048S21CONDENSINGENTERING AIRTEMPERATUREIDCFM 1375 1575 1775ID DB (°F) 85 80 75 85 80 75 85 80 75ID WB (°F) 72 67 63 72 67 63 72 67 6375T.C. 52.8 49.9 45.4 53.5 50.6 46.8 54.2 51.3 48.2S.C. 33.3 32.7 31.5 34.9 34.5 33.6 36.5 36.2 35.7KW 3.14 3.09 3.03 3.15 3.10 3.04 3.17 3.12 3.0685T.C. 50.9 47.1 42.4 51.6 48.1 43.5 52.3 49.1 44.7S.C. 33.3 32.0 30.4 35.3 34.2 32.6 37.4 36.3 34.7KW 3.44 3.35 3.30 3.46 3.38 3.31 3.47 3.40 3.3295T.C. 49.0 44.3 39.4 49.7 45.5 40.3 50.3 46.8 41.2S.C. 33.2 31.2 29.3 35.8 34.1 31.5 38.4 36.5 33.7KW 3.74 3.62 3.57 3.76 3.56 3.57 3.78 3.69 3.58105T.C. 44.7 40.0 35.8 45.4 41.0 36.5 46.1 42.0 37.1S.C. 31.9 29.8 27.8 34.5 32.2 29.9 37.0 34.7 32.1KW 4.01 3.89 3.80 4.04 3.91 3.81 4.07 3.94 3.83115T.C. 40.5 35.7 32.1 41.2 36.5 32.6 41.9 37.2 33.1S.C. 30.5 28.3 26.3 33.1 30.5 28.4 35.7 32.8 30.5KW 4.28 4.15 4.02 4.32 4.17 4.05 4.35 4.19 4.08125T.C. 36.3 31.3 28.5 36.9 31.9 28.8 37.6 32.5 29.1S.C. 29.2 26.8 24.8 31.8 28.9 26.8 34.4 31.0 28.8KW 4.55 4.42 4.25 4.60 4.43 4.29 4.64 4.44 4.33NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.Air Handler Coil T.C. S.C. KWF2FP048 1.00 1.00 1.02F2FP060 1.03 1.03 1.06F2FV060 1.06 1.10 0.95N1AHC1606 G2FD048(S,H)21,24 1.00 1.00 1.01N1AHD2006 G2FD060(S,H)24 1.03 1.03 1.02N1AHD2006 G2FD061H24 1.04 1.04 1.02N1VSC16 G2FD048(S,H)21 1.01 1.02 0.97N1VSD20 G2FD060(S,H)24 1.04 1.06 0.99N1VSD20 G2FD061H24 1.05 1.07 0.99G1FA048S17 0.98 0.98 0.98G1FA060S21,24 1.03 1.03 1.02G1HD048 0.99 0.99 1.01G1HD060 1.02 1.02 1.02G1NA048S21D 0.99 0.99 1.02G1UA048S17 0.98 0.98 0.98G1UA048S21 1.00 1.00 1.00G1UA060S21,24 1.03 1.03 1.02G2FD046(S,H)17 0.98 0.98 1.00G2FD048(S,H)21,24 1.00 1.00 1.01G2FD060(S,H)24 1.03 1.03 1.02G2FD061H24 1.04 1.04 1.02Variable SpeedFurnace Coil T.C. S.C. KWP1DUC20V G1FA048S21 1.00 1.00 0.99P1DUC20V G2FD048(S,H)21 1.00 1.00 1.00P1XDD20V G2FD048(S,H)24 1.01 1.01 1.01P1XUC16V G1FA048S21 0.99 0.99 1.00P1XUC16V G2FD048(S,H)21 0.99 0.98 1.01P1XUC20V G1FA048S21 1.00 1.00 0.99P1XUC20V G2FD048(S,H)21 1.00 1.00 1.00P1XUD20V G1FA060S24 1.04 1.05 1.00P1XUD20V G2FD048(S,H)24 1.01 1.01 0.99P1XUD20V G2FD060(S,H)24 1.04 1.05 1.00