vi SM-16005-rev.2Refrigerant PrecautionsTo reduce the risk of serious injury or death, the following refrigerantprecautions must be followed.● As originally manufactured, this unit contains refrigerant installed by Johnson Controls. JohnsonControls uses only refrigerants that have been approved for use in the unit’s intended home countryor market. Johnson Controls distributors similarly are only authorized to provide refrigerants thathave been approved for use in the countries or markets they serve. The refrigerant used in this unitis identified on the unit’s faceplate and/or in the associated manuals. Any additions of refrigerant intothis unit must comply with the country’s requirements with regard to refrigerant use and should beobtained from Johnson Controls distributors. Use of any non-approved refrigerant substitutes will voidthe warranty and will increase the potential risk of injury or death.● If installed in a small room, take measures to prevent the refrigerant from exceeding the maximumallowable concentration in the event that refrigerant gases should escape. The installation shouldmeet the requirements in ASHRAE Standards 15 and 34. If refrigerant gas has leaked during theinstallation work, ventilate the room immediately.● Check the design pressure for this product is 601 psi (4.15MPa). The pressure of the refrigerantR410A is 1.4 times higher than that of the refrigerant R22. Therefore, the refrigerant piping forR410A shall be thicker than that for R22. Make sure to use the specified refrigerant piping. If not, therefrigerant piping may rapture due to an excessive refrigerant pressure. Besides, pay attention tothe piping thickness when using copper refrigerant piping. The thickness of copper refrigerant pipingdiffers depending on its material.● The refrigerant R410A is adopted. The refrigerant oil tends to be affected by foreign matters suchas moisture, oxide film, (or fat). Perform the installation work with care to prevent moisture, dust, ordifferent refrigerant from entering the refrigerant cycle. Foreign matter can be introduced into the cyclefrom such parts as expansion valve and the operation may be unavailable.● To avoid the possibility of different refrigerant or refrigerant oil being introduced into the cycle, thesizes of the charging connections have been changed from R407C type and R22 type. It is necessaryto prepare the appropriate tools before performing installation work.● Use refrigerant pipes and joints which are approved for use with R410A.● A compressor/unit comprises a pressurized system. Never loosen threaded joints while the system isunder pressure and never open pressurized system parts.● Before installation is complete, make sure that the refrigerant leak test has been performed. Ifrefrigerant gases escape into the air, turn OFF the main switch, extinguish any open flames andcontact your service contractor. Refrigerant (Fluorocarbon) for this unit is odorless. If the refrigerantshould leak and come into contact with open flames, toxic gas could be generated. Also, because thefluorocarbons are heavier than air, they settle to the floor, which could cause asphyxiation.● When installing the unit, and connecting refrigerant piping, keep all piping runs as short aspossible, and make sure to securely connect the refrigerant piping before the compressor startsoperating. If the refrigerant piping is not connected and the compressor activates with the stopvalve opened, the refrigerant cycle can become subjected to extremely high pressure, which cancause an explosion or fire.● Tighten the flare nut with a torque wrench in the specified manner. Do not apply excessive force to theflare nut when tightening. If you do, the flare nut can crack and refrigerant leakage may occur.● When maintaining, relocating, and disposing of the unit, dismantle the refrigerant piping after thecompressor stops.● When pipes are removed out from under the piping cover, after the insulation work is completed,cover the gap between the piping cover and pipes by a packing (field-supplied). If the gap is notcovered, the unit may be damaged if snow, rain water or small animals enter the unit.● Do not apply an excessive force to the spindle valve at the end of opening. Otherwise, the spindlevalve flies out due to refrigerant pressure. At the test run, fully open the gas and liquid valves,otherwise, these devices will be damaged. (It is closed before shipment.)● If the arrangement for outdoor units is incorrect, it may cause flowback of the refrigerant and result infailure of the outdoor unit.● The refrigerant system may be damaged if the slope of the piping connection kit exceeds +15o .