Domestic hot water tankConnection overviewCompact P front310110 24820024012354Compact P backConnections:1. Connection for 3/4” circulation pipe2. Hot water outlet 3/4"3. Cold water intake 3/4"4. Return supplementary coil 3/4"5. Supply supplementary coil 3/4"Supplementary coil is only standard on Compact P SOL models.The coil is located in the bottom, and has an external diameter of 22 mm and is 8,500 mm long,equivalent to 0.6 m 2 .ConnectionATTENTIONAll work must be performed by qualified personnel and in accordance with relevant legislationand provisions.Nilan's hot water tanks are double-enamelled, ensuring long life. The efficient foam insulation protectsagainst unnecessary heat loss.All connection nozzles for water have 3/4" thread and are located in the tank bottom.The tank is also fitted with an electronically-monitored sacrificial anode that automatically displays awarning on the display when it needs changing.Compact P / Compact P Polar - GEO (English) BY NILAN37